Game engine-driven high-precision collision simulation system for radiation therapy: development and clinical evaluation.
Yuri Toyohara
Department of Radiology, Ishikawa Prefectural Central Hospital, 2-1, Kuratsuki higashi, Kanazawa, Ishikawa, 920-8530, Japan. y.toyohara0112@gmail.com.
Key points
From the paper's conclusion- This study aimed to develop virtual collision simulation software using a freely available development environment and to evaluate its performance through phantom studies and verification of clinical treatment plans.
Abstract
Pre-treatment verification is essential to prevent physical collisions between the gantry and the patient during radiation therapy. Conventionally, physical "dry runs" have been performed to ensure safety; however, these procedures can create bottlenecks in clinical workflows. This study aimed to develop virtual collision simulation software using a freely available development environment and to evaluate its performance through phantom studies and verification of clinical treatment plans. High-fidelity three-dimensional (3D) models of the linear accelerator and various immobilization devices were constructed. The software was developed in the Unity environment and incorporated a collision detection system and a function to predict treatment couch coordinates. Collision detection accuracy was assessed using phantom experiments by comparing simulated results with those obtained from the actual linear accelerator. The accuracy of couch coordinate predictions and collision detection performance were retrospectively evaluated using clinical data from 71 treatment plans. All collision prediction errors in the phantom experiments fell conservatively within a 3.00° margin prior to physical contact, and couch coordinate predictions were within 1 cm of the actual values. In the evaluation of clinical plans, the software achieved a true-positive rate of 100% and a negative predictive value of 100%. The developed software achieved high-precision collision detection despite being created in a free platform, thereby ensuring both high performance and broad reproducibility. By serving as an effective pre-screening tool and reducing the need for physical dry runs, this cost-effective and accessible solution streamlines workflow and enhances patient safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A patient-specific Winston-Lutz system for multi-target, single isocentre radiotherapy.Biomedical physics & engineering express · 2026
- A real-time image-guided six-degree-of-freedom internal-external correlation framework for motion monitoring on a standard linear accelerator.Physics in medicine and biology · 2026
- Optimizing TrueBeam jaw calibrations to reduce positional errors at customizable gantry and collimator anglesJournal of Applied Clinical Medical Physics · 2026
- Statistical process control and error curve modelling identify superior pre-treatment verification metrics for nasopharyngeal carcinoma and cervical cancer VMAT: a retrospective studyFrontiers in Oncology · 2026
- Clinical impact of introducing automated plan checking in radiation therapy: effects on workflow efficiency, cognitive load and usability.Journal of radiation research · 2026
- An audiovisual assistance system for beam-stopper positioning in intraoperative electron radiotherapy: experimental evaluation under manual and teleoperated operation.Frontiers in robotics and AI · 2026