European journal of orthopaedic surgery & traumatology : orthopedie traumatologie

3D-CT-guided patient-specific instrumentation versus conventional implants for traumatic malunited distal radius corrective osteotomies: A systematic review and meta-analysis.

Baijaeek Sain, Suraj Suryawanshi, Pranav Mishra, Abdul Moeed, Wasim Qadir, Vishal Patel, Suddhajit Sen, Vasanthakumar Ramsingh

United Lincolnshire Hospitals NHS Trust, Louth, UK. baijaeek.sain@nhs.net. · Royal Berkshire NHS Foundation Trust, Reading, UK.

Meta-analysis

Key points

From the paper's conclusion
  • There was a promising trend towards fewer complications and revision surgery with PSI. Both techniques achieved acceptable radiological restoration, with PSI conferring a modest advantage in ulnar variance but resulting in slight under-correction of volar tilt. Functional outcomes and range of motion improved to a clinically meaningful degree with both approaches, though this was accompanied by substantial heterogeneity between studies. High-quality randomised controlled trials are required to confirm these findings and to justify the additional costs associated with PSI technology.

Abstract

BACKGROUND: Corrective osteotomy for traumatic malunited distal radius fractures has traditionally relied on conventional pre-contoured plates. Patient-specific instrumentation (PSI) with three-dimensional (3D) CT-guided planning offers theoretical advantages through individualised design and improved anatomical fit, but comparative clinical evidence remains limited. We aimed to evaluate functional outcomes and complications following patient-specific versus conventional implants for distal radius corrective osteotomy. METHODS: A comprehensive literature search was conducted according to PRISMA guidelines, including MEDLINE, Embase, Scopus and CINAHL databases for studies published up to September 2025. Clinical studies directly comparing PSI with conventional implants, and single-arm PSI studies, were included. Meta-analyses were performed when two or more studies reported identical outcome measures, using random-effects models. Risk of bias was assessed using the Cochrane tool (RoB-1). RESULTS: Eighteen studies (15 single-arm PSI, three comparative) with 321 patients (282 PSI, 39 conventional) were included; mean follow-up was 14.4 ± 5.5 months and mean age 46.8 ± 7.3 years. For radiological parameters, volar tilt showed a pooled mean difference (MD) of - 8.87° (95% CI - 11.42 to - 6.32; I2 = 0.0%) favouring less volar tilt with PSI; radial inclination showed a pooled MD of - 0.89° (95% CI - 4.19 to 2.41; I² = 0.0%); and ulnar variance a pooled MD of 1.19 mm (95% CI - 0.40 to 2.78; I² =265.9%). Flexion-extension improved by 26.63°, with a final pooled arc of 134.69° (95% CI 117.73 to 154.08). Pronation-supination improved by 23.33°, with a final arc of 159.71° (95% CI 153.83 to 165.81). The pooled complication rate was 4% (95% CI 1% to 7%) and the revision risk ratio was 0.60 (95% CI 0.27 to 1.35; I2 = 0.0%) for PSI. CONCLUSION: There was a promising trend towards fewer complications and revision surgery with PSI. Both techniques achieved acceptable radiological restoration, with PSI conferring a modest advantage in ulnar variance but resulting in slight under-correction of volar tilt. Functional outcomes and range of motion improved to a clinically meaningful degree with both approaches, though this was accompanied by substantial heterogeneity between studies. High-quality randomised controlled trials are required to confirm these findings and to justify the additional costs associated with PSI technology.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

3D-CT-guided patient-specific instrumentation versus conventional implants for traumatic malunited distal radius corrective osteotomies: A systematic review and meta-analysis — Science Skim