Immunologic research

Cell-based ELISA using intact HEp-2 cells: an alternative approach for antinuclear antibody detection.

Faruk Dişli, Sedat Yıldız

Faculty of Physiotherapy and Rehabilitation Department of Basic Physiotherapy, Bingöl University, Bingöl, Turkey. fdisli@bingol.edu.tr. · Faculty of Medicine, Department of Physiology, İnönü University, Malatya, Turkey.

Key points

From the paper's conclusion
  • This study demonstrates that the HEp-2 cell-based ELISA is a feasible, promising method for detecting and quantifying ANA positivity. While it reliably distinguishes between positive and negative samples, it may serve as a practical alternative to conventional assays in research and diagnostics.

Abstract

BACKGROUND: Antinuclear antibodies (ANAs) are serological markers of clinical importance in the diagnosis and monitoring of autoimmune diseases. This study aimed to develop a HEp-2 cell-based ELISA method as a quantitative and standardized alternative to traditional ANA detection techniques such as indirect immunofluorescence (IFA). MATERIALS AND METHODS: HEp-2 cells were seeded in ELISA plates at ~ 3.0 × 10⁴ cells per well and incubated. After fixation with formaldehyde and acetone, cells were quenched with 1% H₂O₂, permeabilized using Triton X-100, acetone, and methanol, and blocked with Well Champion or 1% BSA. Sixteen sera (8 ANA-positive, 8 ANA-negative), confirmed by Chorus ANA-8 and DRG ANA-8-Screen ELISA, were applied. ANA levels were measured by indirect ELISA with OD readings at 450 nm. Three HRP-conjugated secondary antibodies (anti-IgG gamma chain, Fc-specific, whole IgG) were tested. RESULTS: Fixation and permeabilization agents did not interfere with the distinction between ANA-positive and ANA-negative samples. In the absence of quenching and when 1% BSA was used for blocking, background levels increased. Among the secondary antibodies, the anti-IgG gamma chain showed the least cross-reactivity, while Fc-specific and whole IgG antibodies had higher nonspecific binding. The assay showed an average intra- and inter-assay variation of 13.13%, with a sensitivity of 87.5% and a specificity of 81.25%. CONCLUSIONS: This study demonstrates that the HEp-2 cell-based ELISA is a feasible, promising method for detecting and quantifying ANA positivity. While it reliably distinguishes between positive and negative samples, it may serve as a practical alternative to conventional assays in research and diagnostics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Cell-based ELISA using intact HEp-2 cells: an alternative approach for antinuclear antibody detection — Science Skim