Robotic sentinel lymph node biopsy with dual-tracer mapping in 76 patients with breast cancer: high detection rate and low false-negative rate.
Qiwen Liu, Yueyue Teng, Zongyan Li, Tong Wu, Xiaoyan Fu, Yongxin Wu, Haiyan Li
Department of General Surgery (Breast Surgery), The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China. · Department of Thyroid and Breast Surgery, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, China.
Key points
From the paper's conclusion- Sentinel lymph nodes (SLNs) were detected in all 76 patients, corresponding to a detection rate of 100%.
Abstract
Axillary staging in breast cancer increasingly relies on sentinel lymph node biopsy (SLNB), which has an established role in treatment de-escalation. Robotic systems may offer advantages such as reduced blood loss and fewer complications in axillary surgery. However, the evidence supporting the clinical application of robotic systems in SLNB remains insufficient. We evaluated the diagnostic accuracy and safety of robotic sentinel lymph node biopsy (R-SLNB) with dual-tracer mapping. This single-arm retrospective study included 76 patients with breast cancer who received R-SLNB guided by carbon nanoparticles suspension injection (CNSI) plus indocyanine green (ICG). Axillary lymph node dissection (ALND) served as the reference standard. The study analyzed detection rate, false-negative rate (FNR), surgical outcomes, and complications. Sentinel lymph nodes (SLNs) were detected in all 76 patients, corresponding to a detection rate of 100%. The overall FNR was 4.0%. Sensitivity and negative predictive value (NPV) were 96.0% and 92.9%, respectively. When analyzed according to the number of SLNs removed, the FNR was 0% with 1-2 SLNs, 3.3% with 3 SLNs, and 5.6% with at least 4 SLNs. The FNR in the neoadjuvant chemotherapy (NAC) subgroup was 7.1%, whereas that in the non-NAC group was 2.8%. The mean number of SLNs harvested was 3.9 ± 2.2, the mean time to first SLN was 4.3 ± 1.7 min and the mean biopsy time was 10.4 ± 2.8 min. Complications occurred in 13.2% of patients. Among them, lymphedema was documented in four patients (5.3%). There was no conversion to open surgery and no perioperative death. R‑SLNB with dual-tracer mapping demonstrated high accuracy and acceptable short-term safety, with a trend toward a low FNR below the clinical safety threshold in patients receiving neoadjuvant chemotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation Study of Sentinel Lymph Node Biopsy after Neoadjuvant Chemotherapy in Breast Cancer.Indian journal of surgical oncology · 2026
- Outcomes of methylene blue single-dye sentinel lymph node biopsy in early breast cancer: a retrospective cohort study from a resource-limited tertiary centreWorld Journal of Surgical Oncology · 2026
- Combined Use of Savi Scout and Magtrace for Non-Palpable Breast Cancer: A Retrospective Study.Cancers · 2026
- A Multicenter Non‐Inferiority Randomized Controlled Trial of Sentinel Lymph Node Biopsy in Early Breast Cancer: Conventional Dual Tracer Versus Superparamagnetic Iron OxideWorld Journal of Surgery · 2026
- Repeat Sentinel Lymph Node Biopsy in Ipsilateral Breast Tumour Recurrence: A Systematic Review and Meta-Analysis of Technical Feasibility, Nodal Restaging, and Oncological Safety.Cancers · 2026
- Simultaneous Use of Radar and Magnetic Navigation in Breast Cancer Surgery.Cancers · 2026