Outcomes of methylene blue single-dye sentinel lymph node biopsy in early breast cancer: a retrospective cohort study from a resource-limited tertiary centre
Vathsal Chinthaka Bandaranayake, Amila Prathibha Nellihela, Jayanjana Asanthi, Aruna Wijesooriya, Ruchika Nirmalie Senevirathne Jayalathge, Aruna Buddhika Jayasena, Sulakshi Nikeshala Karunanayake, Pirahanthan Karunanithy,
Key points
From the paper's conclusion- Overall recurrence occurred in 5/115 patients (4.3%) over a mean follow-up of 36.3 months.
Abstract
Background Sentinel lymph node biopsy (SLNB) is the standard axillary staging procedure for clinically node-negative early breast cancer. Although dual-tracer mapping provides high sentinel-node identification rates, access to radioisotopes and nuclear medicine facilities remains limited in many resource-constrained healthcare systems. We evaluated the technical performance, recurrence outcomes and tracer-related costs of methylene blue (MB)-only SLNB at a tertiary oncology centre in Sri Lanka. Methods This retrospective cohort study included 115 patients with clinically and radiologically node-negative breast cancer who underwent MB-only SLNB. The sentinel-node identification rate was defined as the proportion of attempted procedures in which at least one blue-stained sentinel lymph node was successfully identified. Secondary outcomes included sentinel-node yield, final nodal histology, additional axillary nodal burden, recurrence outcomes and tracer-related costs. Because patients with negative SLNB did not undergo completion axillary lymph node dissection (ALND), a conventional ALND-referenced false-negative rate could not be calculated. Results Sentinel lymph nodes were successfully identified in 113/115 patients, corresponding to an identification rate of 98.3%. Among the 113 successfully mapped patients, sentinel-node tumour deposits were identified in 40 (35.4%), comprising 33 macrometastases, 5 micrometastases and 2 cases with isolated tumour cells, pN0(i+). Seventy-three patients had negative sentinel nodes. The mean sentinel lymph node yield was 3.25 ± 1.70 nodes (mean ± standard deviation). No isolated axillary recurrences were observed among successfully mapped SLNB-negative patients during follow-up (0/73; exact 95% confidence interval 0–4.9%). Overall recurrence occurred in 5/115 patients (4.3%) over a mean follow-up of 36.3 months. No MB-related adverse reactions were recorded. The MB tracer cost was approximately LKR 330 (US$1.10) per patient, and mapping did not require radioisotope procurement, gamma-probe equipment or nuclear medicine support. Conclusions MB-only SLNB achieved a high identification rate, no observed isolated axillary recurrence after negative mapping during short- to mid-term follow-up, and minimal tracer expenditure. These findings support its technical feasibility and practical value where isotope-supported mapping is unavailable. However, the absence of ALND verification in SLNB-negative patients, few recurrence events and no contemporaneous comparator preclude conclusions regarding false-negative rate, diagnostic equivalence, long-term oncologic safety or formal cost-effectiveness. Prospective multicentre comparative studies with longer follow-up are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sentinel lymph node biopsy using methylene blue-fluorescein dye combination in post neo-adjuvant chemotherapy node negative (ycN0) breast cancer patients: A validation study.Tropical doctor · 2026
- Oncologic Outcomes of Blue Dye-Only Sentinel Lymph Node Biopsy After Neoadjuvant Chemotherapy in Initially Node-Positive Breast Cancer: A Multicenter Cohort Study from the Brazilian Public Health System.Annals of surgical oncology · 2026
- A Multicenter Non‐Inferiority Randomized Controlled Trial of Sentinel Lymph Node Biopsy in Early Breast Cancer: Conventional Dual Tracer Versus Superparamagnetic Iron OxideWorld Journal of Surgery · 2026
- Robotic sentinel lymph node biopsy with dual-tracer mapping in 76 patients with breast cancer: high detection rate and low false-negative rate.Journal of robotic surgery · 2026
- Repeat Sentinel Lymph Node Biopsy in Ipsilateral Breast Tumour Recurrence: A Systematic Review and Meta-Analysis of Technical Feasibility, Nodal Restaging, and Oncological Safety.Cancers · 2026
- Does the Number of Harvested Sentinel Lymph Nodes Matter in Breast Cancer Patients with Limited Nodal Burden? A Descriptive Cohort Study.Medical sciences (Basel, Switzerland) · 2026