Accelerometers improve detection of movement related artifact in bedside ICU data.
Ian Piper, Rob Donald, Katarina Sandall, Annemarie Docherty
Centre for Medical Informatics, The Usher Institute, University of Edinburgh, Edinburgh, UK. · University of Edinburgh Medical School, Edinburgh, UK.
Key points
From the paper's conclusion- We present a small (10 patient) study but with accurately annotated clinical event data constructed by observing standard clinical procedures and merging this information with the physiologic data (ECG, ABP, CVP) from bedside monitors.
Abstract
Routinely collected real time data from ICU bedside monitors is a valuable source of information which can assist the clinical team caring for a patient. This data almost always contains artifacts caused by clinical staff attending to the patient throughout the day, e.g. blood samples being taken, body washing, administration of IV medication. We present a small (10 patient) study but with accurately annotated clinical event data constructed by observing standard clinical procedures and merging this information with the physiologic data (ECG, ABP, CVP) from bedside monitors. In addition, to assess the feasibility for using accelerometers in the ICU environment, we received ethical approval to place an accelerometer [1] on the chest of all patients and the X, Y & Z accelerometer plane data was merged with the physiological and event annotation data. The non-trivial methods required to capture the data and initial characterisation of results are detailed and discussed. A baseline model cross-correlating ECG and ABP waveform signals over a 10 s window was developed and features derived from this model were used in both GLM and Random Forest (RF) models for predicting events that routinely cause movement related artifact in waveform quality time-series data. RF model performance improved when accelerometer data was added to the model for most movement related artifact types. For the GLM models, only selected models (ANY Type, Turns, Bed Movement and Blood Sample) showed an improvement in model fit with the addition of the accelerometer data (P < 0.01). Implications for observational ICU research and potential "Closed Loop" clinical modelling studies are discussed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Data for Machine Learning Models: Clinical Experience Determines Interrater Reliability in Waveform Anomaly Detection.Neurocritical care · 2026
- Motion Artifacts Quantification in Ambulatory Holter ECG Across Age Groups: Insights from Simultaneous 3-Axis AccelerometryJournal of Experimental and Theoretical Analyses · 2026
- Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk CalibrationarXiv · 2026
- Accelerometer-based evaluation of left ventricular diastolic functionEuropean Heart Journal · 2026
- Feasibility of Accelerometer-Based Arterial Pulse Measurement: Part I-Theoretical Analysis.Sensors (Basel, Switzerland) · 2026