arXivPreprintOpen accesscs.LG

Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk Calibration

Zeyu Jia

Key points

From the paper's conclusion
  • We developed a causal signal-conditioning and shift-robust conformal calibration framework across 5,439 public anesthesia procedures.

Abstract

Commercial intraoperative electroencephalography (EEG) and blood pressure monitors introduce cyclic impedance pulses, smoothing delays, direct-current (DC) drift, and cuff holds that confound risk forecasting and uncertainty calibration. We developed a causal signal-conditioning and shift-robust conformal calibration framework across 5,439 public anesthesia procedures. Streaming filters blank 10.13-min 64-Hz impedance checks, apply unclipped post-notch conditioning, separate 63-s suppression-ratio lag, and distinguish three-channel cuff inflations from dropouts across propofol-remifentanil total intravenous anesthesia (TIVA; N = 3,214), volatile anesthesia (N = 2,046), European endoscopy sedation (N = 171), and DC-coupled surgery (N = 8). De-impedanced cortical tree ensembles were compared against deep sequence models, paired with patient-cluster Subgroup-Covariate-Weighted Conformal Risk Control (CRC) and lag-buffered online Conformal Proportional-Integral-Derivative (PID) tracking. Pre-filter blanking removed 97.90% and 97.60% of false flatline conflicts while preserving 99.23% and 98.96% of deep suppression. On unseen TIVA surgeries (N = 525), cortical features achieved area under the precision-recall curve (AUPRC) 0.3135 (1.94% prevalence) and 0.1627 (0.82% lag-free prevalence), with no detectable difference from deep encoders (p >= 0.36) and no cortical gain for hypotension (0.3432 vs. 0.3437, p = 0.784). Zero-retraining volatile transfer (N = 1,048) showed no detectable difference from an end-tidal gas oracle on lag-free suppression (0.0820 vs. 0.0736, p = 0.472). Subgroup-Covariate-Weighted CRC bounded all 70 TIVA shift cells at <= 4.38% (alpha = 5.0%) in 66.32 ms per 30-s epoch. Causal artifact disentangling and shift-aware conformal calibration support reliable real-time intraoperative risk bounds within explicit physiological observability limits.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk Calibration — Science Skim