Motion Artifacts Quantification in Ambulatory Holter ECG Across Age Groups: Insights from Simultaneous 3-Axis Accelerometry
Naoya Morikawa, Emi Yuda
Key points
From the paper's conclusion- We present a data processing pipeline that (1) extracts RRI sequences and computes a comprehensive set of heart rate variability (HRV) metrics (time-domain, frequency-domain, and nonlinear), (2) computes per-epoch accelerometer root mean square (RMS) as a motion intensity proxy, and (3) correlates motion intensity with RRI artifact rate across age groups.
Abstract
Ambulatory Holter electrocardiogram (ECG) monitoring is increasingly used in ambulatory elderly populations; however, age-related physiological and mechanical factors substantially increase susceptibility to motion-induced signal artifacts, limiting reliable heart rate (HR) variability (HRV) analysis. This study aims to quantify age-group differences in motion artifact burden and to establish an age-stratified noise model using simultaneous ECG and three-axis accelerometry. Twenty participants—15 elderly patients (elderly male: OM, n = 10; elderly female: OF, n = 5) and five young males (young male: YM, n = 5)—underwent ambulatory ECG recording during daily life activities. The simultaneous acquisition of three-channel ECG and triaxial acceleration data enables quantitative characterization of motion-induced noise in the R–R interval (RRI) time series. We present a data processing pipeline that (1) extracts RRI sequences and computes a comprehensive set of heart rate variability (HRV) metrics (time-domain, frequency-domain, and nonlinear), (2) computes per-epoch accelerometer root mean square (RMS) as a motion intensity proxy, and (3) correlates motion intensity with RRI artifact rate across age groups. Key findings: Artifact rate was highest in OM (1.9 ± 4.7%) versus OF (0.9 ± 0.9%) and YM (0.3 ± 0.6%); standard deviation (SD) of all normal-to-normal intervals (SDNN) was 72.7 ± 26.5 ms (OM), 95.8 ± 71.8 ms (OF), and 79.6 ± 6.7 ms (YM); and low-frequency-to-high-frequency power ratio (LF/HF) was notably higher in YM (5.04 ± 3.52) than in elderly groups (OM: 1.53; OF: 1.08). Epoch accelerometer RMS was modestly higher in YM (0.317 g) than in elderly groups (OM: 0.306 g; OF: 0.302 g). The findings establish a quantitative framework for age-stratified noise modeling in wearable ECG devices, with direct implications for motion-robust R-peak detection algorithm design. The concurrent availability of ECG and inertial data from a single IEC 60601-certified device distinguishes this dataset from prior art and strengthens its value for signal processing research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inter-Lead RRI Agreement Between Lead I and Lead II Across Diagnostic ECG Categories: Pilot Evidence for Wearable HRV MonitoringApplied Sciences · 2026
- Quantification of Heart Rate Variability as a Digital Biomarker for the Autonomic Control of Cardiac FunctionBiomolecules · 2026
- Recording sampling rate as a negative-control exposure for detecting measurement-driven bias in heart-rate-variability-outcome associations: a quantitative bias analysis across ICU waveform databasesmedRxiv · 2026
- Improving ECG diagnostic performance under ambulatory noise with scalable long-range state-space denoising modellingEuropean Heart Journal · 2026
- Integrated Electrocardiography-Heart Rate Variability (ECG-HRV) Analysis in Neurologically Symptomatic Individuals Without Cardiac Symptoms: A Data-Driven Retrospective Observational Study of Electrocardiographic-Autonomic Associations.Cureus · 2026
- Ambulatory detection of cardiac arrhythmias with wearable PPG sensorsEuropean Heart Journal · 2026