Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing

First-in-human experience from RESET-AF (Rapid onE-Shot Electroporation Trial for Atrial Fibrillation).

Paul A Gould, Stuart P Thomas, Waheed Ahmad, Pierre C Qian, Arash Aryana

Princess Alexandra Hospital, Brisbane, QLD, Australia. Paul.gould2@health.qld.gov.au. · Westmead Hospital, Westmead, NSW, Australia.

Trial

Key points

From the paper's conclusion
  • This study of a novel PFA catheter system for ablation of paroxysmal and persistent AF achieved all predetermined primary and secondary clinical endpoints.

Abstract

BACKGROUND AND AIMS: Pulsed field ablation (PFA) is increasingly used to treat patients with atrial fibrillation (AF). The RESET-AF was a single-arm, first-in-human, clinical trial of AF ablation using a novel, single-shot PFA system (ElePulse®, CRC EP, Tustin, CA, USA), trial registration ACTRN12622001523796 (Date registered 8th December 2022). METHODS: In 36 consecutively-enrolled patients (57 ± 11 years, 69% male) with symptomatic paroxysmal (n = 22) and persistent (n = 14) AF, pulmonary vein isolation (PVI) was performed using this catheter, guided by 3D mapping. All patients underwent remapping at 3 months to confirm PVI durability. Patients were followed at 6 and 12 months with clinical review, Holter monitoring and electrocardiography. The primary efficacy and safety endpoints included a freedom from recurrent AF at 12 months > 50% and serious adverse events (SAE) at 7 and 30 days < 5%, respectively. The secondary efficacy endpoints included 3-month PVI durability > 50% and 6-month freedom from AF > 60%. RESULTS: All endpoints were achieved in the entire study cohort. There was 1 SAE (renal impairment which resolved with conservative management) with a total SAE rate of 2.8%. One patient was lost to follow-up at 12 months with a primary efficacy endpoint of 92% (32/35 patients). The secondary efficacy endpoints were 82% 3-month PVI and 94% (34/36 patients) 6-month freedom from AF. During the study, the PFA dose was adjusted in 3 cohorts. The "optimized subset" had 100% PVI durability and freedom from AF at 6 and 12 months without SAEs. CONCLUSION: This study of a novel PFA catheter system for ablation of paroxysmal and persistent AF achieved all predetermined primary and secondary clinical endpoints.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers