Femtosecond laser-assisted ultrathin/nanothin DSAEK using optical coherence tomography-guided pachymetric oversizing: a retrospective case series.
Jose A Gegundez-Fernandez, Barbara Burgos-Blasco, Mayte Ariño-Gutierrez, Belen Alfonso-Bartolozzi, Carlos Lisa-Fernandez, Luis Fernandez-Vega-Cueto, Rosalía Méndez-Fernández, David Diaz-Valle,
Hospital Clinico San Carlos, Madrid, Spain. doctorgegundez@gmail.com. · Hospital Clinico San Carlos, Madrid, Spain.
Key points
From the paper's conclusion- OCT-guided pachymetric oversizing during femtosecond donor cutting was feasible for preparing ultrathin DSAEK grafts, with a subset in the nanothin range. Exploratory analyses suggested that larger graft diameter and primary case status may be associated with improved clinical outcomes, whereas prior graft failure may be associated with lower success rates.
Abstract
PURPOSE: To describe femtosecond laser donor preparation for ultrathin/nanothin Descemet stripping automated endothelial keratoplasty (DSAEK) using intraoperative optical coherence tomography (OCT) guidance and pachymetric oversizing, and to report outcomes and exploratory factors associated with clinical outcome. METHODS: Retrospective interventional case series. Donor corneas were cut using femtosecond deep lamellar dissection with pachymetric oversizing and the dissection plane was monitored using intraoperative OCT to achieve a graft thickness of approximately 50 μm. Outcomes included intraoperative and 1-month graft thickness, best-corrected visual acuity (BCVA), and endothelial cell density (ECD) at 1 year. Preoperative factors included isolated endothelial failure, retransplantation, aphakia, glaucoma drainage device, iris abnormalities, and prior posterior vitrectomy. RESULTS: Eighteen eyes were included. The mean age was 64.6 years (range 16-89). Mean intraoperative graft thickness was 57.0 μm (range 38-74), decreasing to 49.9 μm at 1 month (range 30-79). Clinical success was achieved in 10 (55.6%) eyes. Postoperative BCVA was better in successful cases (median 0.52 vs. 1.60 LogMAR; P = 0.001). Larger graft diameter was associated with clinical success (mean 7.9 vs. 7.6 mm; P = 0.037). One-year ECD was available for 10 eyes (mean 1,338.3 cells/mm2; range 860-1,900). Primary cases were more likely to achieve success (87.5% vs. 12.5%; P = 0.041), whereas retransplantation showed an exploratory trend toward failure (P = 0.070). CONCLUSION: OCT-guided pachymetric oversizing during femtosecond donor cutting was feasible for preparing ultrathin DSAEK grafts, with a subset in the nanothin range. Exploratory analyses suggested that larger graft diameter and primary case status may be associated with improved clinical outcomes, whereas prior graft failure may be associated with lower success rates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prognostic Factors for Visual Outcomes Following Ultrathin Descemet Stripping Automated Endothelial Keratoplasty: A Retrospective Study.Bioengineering (Basel, Switzerland) · 2026
- Predicting graft thickness in ultrathin DSAEK using a mechanical microkeratome system.BMJ open ophthalmology · 2026
- Thirty-six-month outcomes of femtosecond laser-assisted DSEK and PKP for corneal endothelial decompensation.BMC ophthalmology · 2026
- Success of femtosecond laser-assisted deep anterior lamellar keratoplasty (Femto-DALK): a clinical case series of 42 eyes using an intraoperative optical coherence tomography (iOCT)-guided laser-generated pre-descemet tunnel.BMC ophthalmology · 2026
- Contact Lens-Assisted Femtosecond Laser Harvesting of Donor Bowman Layer Grafts: A Pilot In Vitro Study With Preliminary Clinical Application in Advanced Keratoconus.Cornea · 2026
- Comparative Evaluation of Graft Thickness and Endothelial Cell Loss in Preloaded DSAEK Grafts During Extended Hypothermic Storage.Cornea · 2026