Cornea

Contact Lens-Assisted Femtosecond Laser Harvesting of Donor Bowman Layer Grafts: A Pilot In Vitro Study With Preliminary Clinical Application in Advanced Keratoconus.

Pedro Bertino, Ricardo Machado-Soares, Renata Soares Magalhães, Guilherme Andrade do Nascimento Rocha, Luciene Barbosa de Sousa, Renato Ambrósio

Department of Ophthalmology, Hospital de Olhos INOB, Brasília, Brazil. · Department of Ophthalmology, Unidade Local de Saúde Gaia-Espinho, Porto, Portugal.

Preclinical

Key points

From the paper's conclusion
  • In this pilot study, the CL-assisted FSL protocol proved a reproducible method for harvesting BL grafts. By bypassing the minimum depth constraints of widely used applanation-based FSL platforms, this technique may minimize tissue loss and expand surgical access to BL transplantation for managing advanced KC, pending confirmation in larger series.

Abstract

PURPOSE: To describe and evaluate a pilot technique using a sterile bandage contact lens (CL) as a spacer to overcome the minimum-depth limitations of applanation-based femtosecond laser (FSL) platforms when harvesting thin donor Bowman layer (BL) grafts, with preliminary clinical application in BL transplantation for advanced keratoconus (KC). METHODS: This experimental and interventional case series included 9 in vitro donor corneas and 4 in vivo eyes with progressive KC. A ∼70-μm plano CL was applied to the bare donor stroma. The FSL dissection depth was programmed by adding the intended graft thickness to the CL thickness (110 μm for a ∼40-μm BL graft). Graft thickness and morphology were evaluated via optical coherence tomography (OCT). For the clinical cases, grafts were implanted into FSL-created stromal pockets; in vivo outcomes were limited to anterior segment OCT assessment of graft integration, graft thickness, and central corneal thickness over 12 months of follow-up. RESULTS: The combined success rate for graft preparation was 92.3% (12/13). In vitro BL grafts yielded a median central thickness of 70 μm. The in vivo BL grafts achieved a median central thickness of 46 μm, with a median deviation of 1.5 μm from the individualized targets. Over the 12-month follow-up, anterior segment OCT showed all grafts to remain well integrated within the stromal pocket, with no displacement or interface complications. CONCLUSIONS: In this pilot study, the CL-assisted FSL protocol proved a reproducible method for harvesting BL grafts. By bypassing the minimum depth constraints of widely used applanation-based FSL platforms, this technique may minimize tissue loss and expand surgical access to BL transplantation for managing advanced KC, pending confirmation in larger series.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers