Prognostic Factors for Visual Outcomes Following Ultrathin Descemet Stripping Automated Endothelial Keratoplasty: A Retrospective Study.
Dongyoung Lee, Yeo Kyoung Won, Tae-Young Chung, Dong Hui Lim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea.
Key points
From the paper's conclusion- We retrospectively reviewed 87 ultrathin DSAEK procedures in 79 eyes (graft thickness, 42–100 μm) with at least 6 months of follow-up.
Abstract
The relationship between donor graft thickness and visual recovery after Descemet stripping automated endothelial keratoplasty (DSAEK) is well recognized, but whether differences in thickness within the ultrathin range affect visual outcomes remains unclear. We retrospectively reviewed 87 ultrathin DSAEK procedures in 79 eyes (graft thickness, 42-100 μm) with at least 6 months of follow-up. Six-month best spectacle-corrected visual acuity (BSCVA), expressed as the logarithm of the minimum angle of resolution (logMAR), was analyzed as a continuous outcome using univariable and multivariable linear regression. An exploratory receiver operating characteristic (ROC) analysis was also performed. Mean logMAR BSCVA improved from 1.44 preoperatively to 0.36 at 6 months. Worse preoperative BSCVA (B = 0.127, p = 0.018) and thicker donor grafts (0.07 logMAR per 10 μm; 95% confidence interval [CI], 0.03-0.10; p < 0.001) were independently associated with worse 6-month visual acuity. Eyes with worse preoperative BSCVA showed greater visual improvement (p < 0.001). Previous glaucoma surgery was not independently associated with visual outcome among eyes whose grafts remained clear for 6 months. The ROC-derived graft-thickness threshold was 68.5 μm (area under the curve [AUC], 0.640). Within the ultrathin range, thinner grafts and better preoperative vision were associated with better 6-month visual outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting graft thickness in ultrathin DSAEK using a mechanical microkeratome system.BMJ open ophthalmology · 2026
- Comparative Evaluation of Graft Thickness and Endothelial Cell Loss in Preloaded DSAEK Grafts During Extended Hypothermic Storage.Cornea · 2026
- Comparative Outcomes From 969 Endothelial Keratoplasties.Cornea · 2026
- Donor endothelial grading and specular images did not measurably improve graft-failure prediction over a clinical reference in the Cornea Preservation Time StudyFrontiers in Medicine · 2026
- Predictors of graft survival after descemet membrane endothelial keratoplasty in eyes with severe corneal edema.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Comparative analysis of outcomes of surface ablation for myopic astigmatism in patients after PKP and DALK.European journal of ophthalmology · 2026