Low-Density sEMG Four-Finger Recalibration with Limited Calibration Data via Classwise Amplitude and Covariance Adaptation of Prior Training Data.
Jiwoong Won, Masami Iwase
Advanced Multidisciplinary Engineering, Graduate School of Advanced Science and Technology, Tokyo Denki University, Tokyo 120-8551, Japan.
Key points
From the paper's conclusion- These findings support the feasibility of participant-specific recalibration for Stable Motion four-finger classification after sensor re-donning and warrant further evaluation in broader user populations and continuous-operation settings.
Abstract
Sensor re-donning can alter surface electromyography (sEMG) amplitudes and inter-channel relationships, degrading sEMG-based motion classifiers. This study proposes personalized recalibration for four-finger motion classifiers and evaluates whether reusing prior Training data can reduce newly acquired Calibration data. Limited labeled Calibration data transform Training signals toward the current condition via classwise amplitude correction and classwise regularized covariance alignment before support vector machine retraining. Three able-bodied male participants (P1-P3) were evaluated using Stable Motion window-level accuracy. For P1, accuracy pooled over ten Test datasets from five re-donning conditions increased from 88.90% to 98.88%. For P2 and P3, exploratory post hoc analyses of four failure-case directions per participant showed pooled accuracy increasing from 24.46% to 98.97% and from 73.74% to 96.72%, respectively. Across exhaustive retrospective analyses of all shared two-of-five repetition subsets, Combined accuracy was 98.29%, 98.68%, and 95.58% for P1-P3, respectively, only 0.18-0.58 percentage points below the five-repetition results; prospectively shortened Calibration recordings were not evaluated. These findings support the feasibility of participant-specific recalibration for Stable Motion four-finger classification after sensor re-donning and warrant further evaluation in broader user populations and continuous-operation settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Subject Pretraining Enables Short-Calibration Personalization for Closed-Corpus Surface EMG Speech DecodingarXiv · 2026
- A phase decoder for reconstructing missing muscle activitybioRxiv · 2026
- Electrode-Level Low-Dimensionality Does Not Guarantee Sensor Redundancy: Dual-Dataset, Participant-Grouped Validation of Parsimonious Myoelectric Gesture Decoding.Biomimetics (Basel, Switzerland) · 2026
- Improving the Clinical Utility of Lower-Limb Surface Electromyography (sEMG) by Quantifying and Correcting for Location Changes in Inter-Session Recordings.Annals of biomedical engineering · 2026
- Cross-device calibration of wearable sEMG gesture recognition using spatio-spectral encoding and frozen-statistic adaptation.Computer methods in biomechanics and biomedical engineering · 2026
- Cross-Recording Handwritten Digit Decoding from sEMG Using a Compact CNN-Transformer and Few-Shot AdaptationbioRxiv · 2026