Disentangling the Hemodynamic Effects of A-Wave Loss and Cardiac Output Reduction in Atrial Fibrillation.
Hailey LaBonte, Ahmad Bshennaty, Ghasaq Saleh, Salameh Al-Halaseh, Mohamad Alkhouli, Hoda Hatoum
Department of Biomedical Engineering, Michigan Technological University, Houghton, MI, USA. · Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
Key points
From the paper's conclusion- Waveform modifications representing AF-related alterations promoted hemodynamic conditions associated with increased flow stasis, with the magnitude of these effects depending on CO and patient anatomy. CO restoration alone did not fully normalize atrial flow organization, suggesting that A-wave loss contributes to impaired LA washout and altered near-wall hemodynamics independent of bulk flow restoration.
Abstract
PURPOSE: Atrial fibrillation (AF) increases thromboembolic risk, yet the relative hemodynamic contributions of A-wave loss, cardiac output (CO) reduction, and patient-specific atrial geometry remain incompletely understood. This study aimed to isolate the hemodynamic consequences of A-wave removal and CO reduction on left atrial (LA) flow and stasis. METHODS: Five patient-specific LA geometries were evaluated using transient laminar CFD simulations. For each geometry, the sinus rhythm transmitral waveform was used as the baseline and modified to represent AF with compromised and conserved CO. Hemodynamic endpoints included LA velocity, time-averaged wall shear stress (TAWSS), relative residence time (RRT), oscillatory shear index (OSI), divergence of the average wall shear stress (AWSS), and threshold-defined blood stasis metrics. RESULTS: Analysis of the pooled spatial distributions across the 5 patient geometries showed that AF-compromised CO conditions resulted in decreased LA velocity, decreased TAWSS (0.788 to 0.508 Pa), increased RRT, and increased blood stasis regions based on velocity (61.8%), TAWSS (86.7%), and RRT (88.5%). When CO was conserved under AF conditions, peak velocity and pooled TAWSS were partially restored (0.508 to 0.827 Pa), with reductions in pooled RRT and threshold-defined stasis ratios (velocity: 42.5%; TAWSS: 59.8%; RRT: 71.7%); however, flow organization, near-wall transport patterns, and several stasis-related metrics remained altered relative to sinus rhythm despite CO restoration. Changes in AWSS indicated altered near-wall flow organization following A-wave removal. CONCLUSION: Waveform modifications representing AF-related alterations promoted hemodynamic conditions associated with increased flow stasis, with the magnitude of these effects depending on CO and patient anatomy. CO restoration alone did not fully normalize atrial flow organization, suggesting that A-wave loss contributes to impaired LA washout and altered near-wall hemodynamics independent of bulk flow restoration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement of left atrial appendage blood transport in patients with atrial fibrillation using dynamic contrast 4DCT.Journal of cardiovascular computed tomography · 2026
- Volume-Constrained Wall Motion Alters Left Atrial Appendage Hemodynamic Descriptors: A CFD Sensitivity Study.Medical engineering & physics · 2026
- Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulationsbioRxiv · 2026
- Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics.International journal for numerical methods in biomedical engineering · 2026
- Thromboembolism in the left atrial appendage under atrial fibrillation and after sinus rhythm restoration: a computational study.Frontiers in bioengineering and biotechnology · 2026
- An integrated fluid-dynamic and structural pipeline to assess atrial hemodynamics before and after left atrial appendage occluder deployment in a patient-specific anatomy.Medical & biological engineering & computing · 2026