Journal of cardiovascular computed tomography

Measurement of left atrial appendage blood transport in patients with atrial fibrillation using dynamic contrast 4DCT.

Lauren Severance, Francisco Contijoch, Imran Mahmud, Taylor Buchalla, Frederick Han, Alejandro Gonzalo, Bahetihazi Maidu, Clarissa Bargellini,

Department of Bioengineering, UC San Diego, La Jolla, CA, USA. · Department of Bioengineering, UC San Diego, La Jolla, CA, USA; Department of Radiology, UC San Diego, La Jolla, CA, USA.

Key points

From the paper's conclusion
  • 4DCT-based voxel-wise quantification of LAA contrast transport using gamma-variate modeling is technically feasible. Further studies are required to determine its potential value for personalized stroke-risk assessment.

Abstract

BACKGROUND: Current stroke risk stratification in atrial fibrillation (AF) relies on clinical factors with known limitations. Blood stasis in the Left Atrial Appendage (LAA) promotes thrombus formation, contributing to embolic stroke. Our objective is to map contrast transport throughout the LAA volume with 4DCT. METHODS: Patients being treated for AF underwent dynamic contrast 4DCT. Hounsfield unit (HU) vs. time curves were fitted voxel wise using gamma-variate models. Three LAA blood transport metrics were extracted: (1) increase in residence time between distal LAA voxels and the LA/LAA orifice (ΔRT); (2) ratio of peak HU enhancement in distal LAA voxels to peak HU in the LA/LAA orifice (ΔHU); and (3) total volume of delayed filling (Vstasis) in the LAA. A composite "LAA Transport Index" (LAATI) was computed using principal component analysis. RESULTS: Among all 93 patients, a wide range of delayed transport in the LAA was observed with: 0 ​< ​ΔRT ​< ​30 ​s, 0.02 ​< ​ΔHU ​< ​1, 0 ​< ​Vstasis ​< ​13 ​mL. Patients imaged during sinus rhythm (n ​= ​26) had rapid filling of the entire LAA with 0 ​< ​ΔRT ​< ​4.7 ​s, 0.65 ​< ​ΔHU ​< ​1, 0 ​< ​Vstasis ​< ​1.0 ​mL. In comparison, patients in AF had values over the entire range ΔRT, ΔHU and Vstasis. For patients imaged in sinus the mean LAATI ​= ​-1.06 ​± ​0.4, and for those imaged in AF the mean LAATI ​= ​0.43 ​± ​1.7. LAATI did not correlate with CHA2DS2-VASc (p ​= ​0.44) or chicken wing morphology (p ​= ​0.21). CONCLUSIONS: 4DCT-based voxel-wise quantification of LAA contrast transport using gamma-variate modeling is technically feasible. Further studies are required to determine its potential value for personalized stroke-risk assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Measurement of left atrial appendage blood transport in patients with atrial fibrillation using dynamic contrast 4DCT — Science Skim