Interventional Embolization Under Multifactorial Coupling: Mechanisms of Embolic-Agent Distribution and Feasibility of Closed-Loop Automatic Injection.
Dongcheng Ren, Xingyuan Li, Shijie Guo, Yang Li, Bo Zhou
School of Mechanical Engineering, Hebei University of Technology, 5340 Xiping Rd., Tianjin, 300400, China. · School of Mechanical Engineering, Hebei University of Technology, 5340 Xiping Rd., Tianjin, 300400, China. liyang@hebut.edu.cn.
Key points
From the paper's conclusion- By reframing embolization as a coupled transport and control problem, this review integrates multifactorial distribution mechanisms with multimodal feedback concepts and outlines a preliminary engineering framework for future feedback-informed embolic-agent delivery systems.
Abstract
PURPOSE: This narrative review aims to synthesize current knowledge on the mechanisms governing embolic-agent distribution and to examine the engineering rationale and translational feasibility of closed-loop or semi-automated embolic-agent injection. METHODS: A structured search and targeted review of experimental, computational, and clinical studies were used to synthesize evidence on particle properties, injection parameters, hemodynamics, imaging feedback, and pressure monitoring related to embolization. Evidence was analyzed from a biomedical engineering perspective, with emphasis on transport mechanisms, sensing modalities, and control-relevant variables. RESULTS: Embolic-agent distribution arises from the coupled effects of particle size, shape, and material properties; injection rate, mode, and catheter configuration; and lesion- and device-induced hemodynamic alterations. Quantitative digital subtraction angiography (qDSA and 4D-DSA) provides spatial and perfusion-related information, whereas local arterial pressure more directly reflects distal resistance evolution and reflux tendency. Taken together, these findings support an engineering interpretation of embolization as a constrained transport-flow-control process in which embolic distribution, endpoint assessment, and procedural safety are jointly influenced by particle characteristics, hemodynamics, and feedback-informed injection strategy. CONCLUSION: By reframing embolization as a coupled transport and control problem, this review integrates multifactorial distribution mechanisms with multimodal feedback concepts and outlines a preliminary engineering framework for future feedback-informed embolic-agent delivery systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gravity-driven flow for intracranial saccular aneurysm filling.Journal of the Royal Society, Interface · 2026
- Soft-Robotic Magnetic Microfluidic Catheter for Delivery of Aqueous-Based Dual-Component Embolic FormulationsbioRxiv · 2026
- On‐Demand Operando Embolization by Rapid Sonodynamic Gelation of Liquid Metal‐Embedded Hydrogels for Effective and Durable Tumor TreatmentAdvanced Materials · 2026
- Balloon-Occluded Transarterial Chemoembolization for Hepatocellular Carcinoma: Technical Rationale, Current Evidence, and Future Directions.Journal of hepatocellular carcinoma · 2026
- Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization proceduresFrontiers in Public Health · 2026
- Design and Applications of Magnetically Actuated Microrobots in Endovascular EmbolizationACS Nano · 2026