Association of axial elongation with the positions of the lateral rectus muscle insertion and the ora serrata.
Gen Shimizu, Genichiro Kishino, Akiko Ohno-Tanaka, Keigo Sugisawa, Yuichiro Tanaka, Kyoko Ohno-Matsui
Department of Ophthalmology and Visual Science, Institute of Science Tokyo Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan. genrasu.999@gmail.com. · Kozawa Eye Hospital and Diabetes Center, Mito, Ibaraki, Japan.
Key points
From the paper's conclusion- LR insertion position was relatively stable across axial lengths, whereas the ora serrata shifted posteriorly with increasing axial length. The increasing ora-LR distance suggests dissociation between extraocular muscle insertion and peripheral retinal anatomy in axial myopia.
Abstract
PURPOSE: To investigate associations of axial length with lateral rectus (LR) muscle insertion and ora serrata positions. STUDY DESIGN: Two-center prospective observational study METHODS: Using swept-source anterior segment optical coherence tomography, we measured distances from the angle recess to the LR insertion and the ora serrata in adult right eyes. Interobserver agreement for LR insertion was assessed using ICC(2, 1) and Bland-Altman analysis. Associations with axial length were evaluated using group comparisons, linear regression, exploratory segmented regression, and age-adjusted regression. The intra-eye ora-LR distance was calculated as the ora serrata distance minus the LR insertion distance. RESULTS: Of 68 eyes included in the interobserver reliability assessment, 4 were excluded based on a prespecified Bland-Altman criterion, leaving 64 eyes for LR insertion analysis. The ora serrata was evaluable in 62 eyes. LR insertion measurements showed good interobserver reliability (ICC(2, 1) = 0.811). LR insertion distance did not differ between axial length groups (p = 0.582) and showed no significant linear association with axial length (p = 0.425). Segmented regression suggested a possible trend change around 26.3 mm, but was exploratory. In contrast, ora serrata distance and ora-LR distance were significantly greater in eyes with axial length ≥26.5 mm and were positively associated with axial length, including after age adjustment. CONCLUSIONS: LR insertion position was relatively stable across axial lengths, whereas the ora serrata shifted posteriorly with increasing axial length. The increasing ora-LR distance suggests dissociation between extraocular muscle insertion and peripheral retinal anatomy in axial myopia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Length Estimation Using Metadata From Swept-Source Optical Coherence Tomography Angiography.Investigative ophthalmology & visual science · 2026
- Repeatability of Swan600 and Its Agreement with Lenstar LS900 for Ocular Biometry in Children.Diagnostics (Basel, Switzerland) · 2026
- Layer-Specific Associations of Axial Length With Retinal and Choroidal Thickness: A Nationally Representative Population-Based Study.Investigative ophthalmology & visual science · 2026
- Agreement between slit lamp retroillumination pictures and Scheimpflug retroillumination display for toric IOLs orientation.Journal of cataract and refractive surgery · 2026
- Association between peripheral retinal lesions and ocular biometric parameters in adults with mild-to-moderate myopia attending a refractive surgery clinic.Frontiers in medicine · 2026
- Comparison of anterior segment parameters in cataract patients with different axial lengths using IOL Master and Pentacam.BMC ophthalmology · 2026