Japanese journal of ophthalmology

Association of axial elongation with the positions of the lateral rectus muscle insertion and the ora serrata.

Gen Shimizu, Genichiro Kishino, Akiko Ohno-Tanaka, Keigo Sugisawa, Yuichiro Tanaka, Kyoko Ohno-Matsui

Department of Ophthalmology and Visual Science, Institute of Science Tokyo Hospital, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan. genrasu.999@gmail.com. · Kozawa Eye Hospital and Diabetes Center, Mito, Ibaraki, Japan.

Key points

From the paper's conclusion
  • LR insertion position was relatively stable across axial lengths, whereas the ora serrata shifted posteriorly with increasing axial length. The increasing ora-LR distance suggests dissociation between extraocular muscle insertion and peripheral retinal anatomy in axial myopia.

Abstract

PURPOSE: To investigate associations of axial length with lateral rectus (LR) muscle insertion and ora serrata positions. STUDY DESIGN: Two-center prospective observational study METHODS: Using swept-source anterior segment optical coherence tomography, we measured distances from the angle recess to the LR insertion and the ora serrata in adult right eyes. Interobserver agreement for LR insertion was assessed using ICC(2, 1) and Bland-Altman analysis. Associations with axial length were evaluated using group comparisons, linear regression, exploratory segmented regression, and age-adjusted regression. The intra-eye ora-LR distance was calculated as the ora serrata distance minus the LR insertion distance. RESULTS: Of 68 eyes included in the interobserver reliability assessment, 4 were excluded based on a prespecified Bland-Altman criterion, leaving 64 eyes for LR insertion analysis. The ora serrata was evaluable in 62 eyes. LR insertion measurements showed good interobserver reliability (ICC(2, 1) = 0.811). LR insertion distance did not differ between axial length groups (p = 0.582) and showed no significant linear association with axial length (p = 0.425). Segmented regression suggested a possible trend change around 26.3 mm, but was exploratory. In contrast, ora serrata distance and ora-LR distance were significantly greater in eyes with axial length ≥26.5 mm and were positively associated with axial length, including after age adjustment. CONCLUSIONS: LR insertion position was relatively stable across axial lengths, whereas the ora serrata shifted posteriorly with increasing axial length. The increasing ora-LR distance suggests dissociation between extraocular muscle insertion and peripheral retinal anatomy in axial myopia.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Association of axial elongation with the positions of the lateral rectus muscle insertion and the ora serrata — Science Skim