Deep-learning-based contrast synthesis in knee magnetic resonance imaging: performance across multiple target contrasts.
Olli Nykänen, Marko Nikki, Victor Casula, Riccardo Lattanzi, Mikko J Nissi, Miika T Nieminen, Mika T Nevalainen
Research Unit of Health Sciences and Technology, Faculty of Medicine, University of Oulu, Oulu, Finland. olli.nykanen@uef.fi. · Department of Diagnostic Radiology, Oulu University Hospital, 90220, Oulu, Finland.
Key points
From the paper's conclusion- The image quality gap observed earlier persisted in this study and manifested itself steadily across all the joint tissues. Synovitis assessment was not possible from the synthetic contrast-enhanced images.
Abstract
INTRODUCTION: Quantitative MRI has been held back, because it increases scan time on top of clinical protocols. In this cross-sectional study, we explore how accurately unmeasured contrasts can be synthesized from magnetic resonance fingerprinting (MRF) data. MATERIALS AND METHODS: MRF, T1-weighted (T1w), gadolinium-enhanced T1w fat-saturated (Gd T1w fs), and double-echo steady-state (DESS) data were acquired at 3 T from volunteers having knee joint symptoms (n=88). Ten subjects were excluded due to missing MRF-data. U-Nets were trained to synthesize the other contrasts out of the MRF data, and the image quality was evaluated for both the synthetic and conventional by two radiologists. Presence of synovitis was evaluated from Gd T1w fs images. Wilcoxon signed-rank test was utilized to test differences in the image quality scores. RESULTS: Synthetic images overall had only slightly lower image quality in radiologists' evaluation for T1w (3.54 vs 3.88, p<0.01), DESS (3.22 vs 3.90, p<0.01), and Gd T1w fs images (3.40 vs 3.76, p<0.01). Synovitis could not be reliably observed from synthetic Gd T1w fs images. CONCLUSIONS: The image quality gap observed earlier persisted in this study and manifested itself steadily across all the joint tissues. Synovitis assessment was not possible from the synthetic contrast-enhanced images.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence for Gadolinium-Sparing Detection of Active Multiple Sclerosis Lesions: A Structured Narrative Review.Neurology and therapy · 2026
- NeCS-Flow: Necrosis-Guided Contrast-Enhanced MRI Synthesis with Rectified-Flow Refinement.bioRxiv : the preprint server for biology · 2026
- Image quality evaluation of dual deep learning accelerated post-contrast Magnetization Prepared Rapid Gradient Echo (MPRAGE) imaging at 1.5 T and 3 T MRI.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- A unified and domain-robust framework enables controllable multimodal brain MRI synthesis.Medical image analysis · 2026
- Deep Learning-Based Gadolinium-Free Virtual Contrast-Enhanced MRI for Predicting Immediate HIFU Ablation Outcomes in Uterine Fibroids.Academic radiology · 2026
- High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) RegularizationarXiv · 2026