Deep Learning-Based Gadolinium-Free Virtual Contrast-Enhanced MRI for Predicting Immediate HIFU Ablation Outcomes in Uterine Fibroids.
Chengwei Li, Hongjian Liao, Jian Liu, Keying Li, Xin Peng, Zhibo Xiao, Jin Gao
Department of Radiology, The Third People's Hospital of Chengdu, Chengdu, China (C.L., H.L., J.L., K.L., X.P., J.G.). · Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China (Z.X.).
Key points
From the paper's conclusion- The mask-guided 3D-cGAN enabled the generation of high-fidelity, gadolinium-free Syn-CE-T1WI that may support noninvasive prediction of immediate HIFU ablation outcomes in uterine fibroids.
Abstract
RATIONALE AND OBJECTIVES: Accurate assessment of microvascular perfusion is essential for predicting high-intensity focused ultrasound (HIFU) ablation outcomes in uterine fibroids. Contrast-enhanced T1-weighted imaging (CE-T1WI) is widely used for vascular evaluation; however, gadolinium-based agents pose safety concerns and may interfere with temperature monitoring. This study aimed to generate synthetic CE-T1WI (Syn-CE-T1WI) from T2-weighted imaging (T2WI) using deep learning for predicting immediate HIFU ablation outcomes. MATERIALS AND METHODS: A mask-guided 3D conditional generative adversarial network (3D-cGAN) was developed using magnetic resonance imaging data from 300 patients (240 training, 60 testing). Syn-CE-T1WI was generated from T2WI. Image quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), and mean absolute error (MAE). Three radiologists performed blinded evaluations of image authenticity and quality. A binary classification task was used to compare Syn-CE-T1WI and Real-CE-T1WI for predicting HIFU outcomes. RESULTS: In the test set, PSNR was 27.05 ± 2.21 dB, SSIM was 0.825 ± 0.12, and MAE was 0.023. Radiologists achieved a mean accuracy of 52.8% in distinguishing real from synthetic images (all P > 0.05). Overall, 88.9% of Syn-CE-T1WI were rated clinically acceptable. For outcome prediction, Syn-CE-T1WI achieved areas under the receiver operating characteristic curve (AUCs) of 0.713-0.763, comparable to Real-CE-T1WI (0.725-0.775; all P > 0.05). Combining Syn-CE-T1WI with T2WI yielded AUCs of 0.775-0.800, numerically higher than T2WI alone (0.713-0.763), and similar to T2WI + Real-CE-T1WI (0.800-0.813; all P > 0.05). CONCLUSION: The mask-guided 3D-cGAN enabled the generation of high-fidelity, gadolinium-free Syn-CE-T1WI that may support noninvasive prediction of immediate HIFU ablation outcomes in uterine fibroids.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- NeCS-Flow: Necrosis-Guided Contrast-Enhanced MRI Synthesis with Rectified-Flow Refinement.bioRxiv : the preprint server for biology · 2026
- A conditional generative model for T2-weighted prostate MRI with downstream evaluation in clinically significant cancer classificatioarXiv · 2026
- Deep-learning-based contrast synthesis in knee magnetic resonance imaging: performance across multiple target contrasts.Magma (New York, N.Y.) · 2026
- DAF: Deterministic affinity-guided latent flow for flexible many-to-many multiphase liver MRI synthesis.Medical image analysis · 2026
- CMIF: Cross-Modality Interactive Fusion for Diffusion-Based MRI Synthesis and Its Impact on Brain Tumor Segmentation.Sensors (Basel, Switzerland) · 2026
- Dual-discriminator Generative Adversarial Network (DD-GAN) for Virtual Elastography Ultrasound in Thyroid Cancer Diagnosis.Academic radiology · 2026