Teacher-Referenced Heatmap Coverage for Auditing Attribution Shifts in Updated CT Classifiers.
Jiaqiang Zhang, Shaodi Wen, Xiaoyue Du, Xutao Jia, Jinshan Shi, Dongyang Du, Ru Li, Bo Shen
College of Computer Science, Inner Mongolia University, No. 235 West University Road, 010021, Hohhot, Inner Mongolia, China. · Department of Oncology, The Affiliated Cancer Hospital of Nanjing Medical University and Jiangsu Cancer Hospital, No. 42 Baiziting Road, 210009, Nanjing, Jiangsu, China.
Key points
From the paper's conclusion- This study evaluated whether peak-aware heatmap measures could provide a more informative signal than thresholded overlap for auditing such changes.
Abstract
Model updates may change the attribution patterns of computed tomography (CT) classifiers without producing corresponding changes in predictive performance. This study evaluated whether peak-aware heatmap measures could provide a more informative signal than thresholded overlap for auditing such changes. Gradient-weighted class activation mapping (Grad-CAM) maps from baseline and decision-distilled ResNet18 classifiers were compared with a frozen, model-derived reference. The primary Heatmap Coverage Metric (HCM) endpoints measure missed circular coverage and nearest-peak distance from the reference to the evaluated map; the reverse direction was analyzed separately. Three held-out CT cohorts were evaluated at the slice level with three training seeds. Fixed-threshold intersection over union was frequently near zero. On the designated seed-42 tests, decision distillation increased circular discrepancy on Priv-EGFR by 0.083 (95% confidence interval, 0.032-0.137), decreased Euclidean discrepancy on Chest CT-Scan by 0.026 (95% confidence interval, - 0.037 to - 0.016 ), and produced inconclusive changes for both RADGEN endpoints. Both primary Chest endpoints were numerically lower under decision distillation in all three seeds, whereas Priv-EGFR and RADGEN showed endpoint- or seed-dependent behavior. Direction reversal changed some small or uncertain effects. Direction is an essential part of the HCM specification. The corrected endpoints complement thresholded overlap by detecting and characterizing update-related attribution shifts under a fixed audit protocol; they measure internal consistency rather than clinical correctness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation studyarXiv · 2026
- Leakage-Safe Auditing of Attribution-Driven Data Curation in Medical ImagingarXiv · 2026
- Improving Data Quality, Model Transparency and Performance in Lung Histopathology with Explainable AI.SLAS technology · 2026
- Clinical selectivity and failure modes of automated chest radiograph report evaluation metrics: a cross-dataset analysis of ReXErr-v1 and RadEvalXmedRxiv · 2026
- Localization Gains from Explanation Regularization Should Not Be Interpreted as Faithfulness Gains.arXiv · 2026
- Detectable, Task-Relevant, or Harmful? Construct-Valid Evaluation of Unlabeled Distribution-Shift Monitoring in Chest Radiography.Journal of imaging · 2026