Clinical selectivity and failure modes of automated chest radiograph report evaluation metrics: a cross-dataset analysis of ReXErr-v1 and RadEvalX
J. Naidu, S. Muralidharan, A. Prashani, V. Baskaradoss
Key points
From the paper's conclusion- Methods: Cross-dataset evaluation used ReXErr-v1 (2,708 report pairs; 5,724 paired error sentences) and 100 RadEvalX report pairs with expert error counts.
Abstract
Objectives: To test whether radiology report evaluation metrics distinguish clinically meaningful errors from textual changes and align with radiologist-assessed error burden. Methods: Cross-dataset evaluation used ReXErr-v1 (2,708 report pairs; 5,724 paired error sentences) and 100 RadEvalX report pairs with expert error counts. BLEU-4, ROUGE-L and METEOR were assessed in ReXErr-v1; RadEvalX analyses included these plus BERTScore, CheXbert, RadGraph F1 and RadCliQ. Outcomes were ReXErr-v1 pairwise win rate and AUROC for clinical-content versus linguistic errors, and RadEvalX Spearman correlation with clinically significant error count and AUROC for any significant error. Confidence intervals used 10,000 clustered percentile bootstrap resamples; Holm adjustment-controlled multiplicity. Results: ReXErr-v1 paired-sentence win rates were 0.986 for BLEU-4, 0.999 for ROUGE-L and 0.998 for METEOR, but discrimination of clinical-content from linguistic errors was modest (AUROC 0.609-0.620). Penalty magnitude was strongly associated with textual change after adjustment for error type (normalised character edit distance coefficient 0.746; 95% CI 0.705-0.788; P<0.001). In RadEvalX, CheXbert showed the highest correlation with clinically significant errors (rho=0.413; 95% CI 0.223-0.578) and highest AUROC (0.742; 95% CI 0.638-0.836). Conclusions: Near-ceiling sensitivity to textual corruption did not imply sensitivity to clinical significance. CheXbert showed the highest alignment with expert error assessment, although pairwise superiority was not demonstrated over all comparators and performance remained moderate.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image EvidencearXiv · 2026
- RadRef: A Reference-Free Metric for Radiology Report GenerationarXiv · 2026
- Error Detection and Correction in Chinese Radiology Reports Using Large Language Models: Real-World Clinical Validation Study.Journal of medical Internet research · 2026
- GPT-4.1 and Llama 3.3 70 fail to detect clinically relevant errors in radiology reports in zero-shot evaluationEuropean Radiology · 2026
- Reliability-Aware Clinical Relation Learning for Uncertainty-Robust Multi-Label Chest X-ray ClassificationmedRxiv · 2026
- Ordinal uncertainty grading in chest radiograph reports using large language models: a REFINE-aligned feasibility and methodology study.Diagnostic and interventional radiology (Ankara, Turkey) · 2026