Using of artificial intelligence to evaluate image quality for interproximal bone level assessment on bitewing radiographs.
Carolina Tiemi Kuteken, Thiago de Oliveira Gamba, Rafael de Mattos Hahn, André Luis Martinotto, Mariana Boessio Vizzotto, Michael Marc Bornstein, Heraldo Luís Dias da Silveira
Department of Oral Surgery and Orthopedics, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, Brazil. · Graduate Program in Applied Computing, University of Caxias do Sul, Caxias do Sul, Brazil.
Key points
From the paper's conclusion- The AI model accurately segmented and classified whether or not vertical angulation was compromising the quality of bitewing radiographs, thereby minimizing errors in the diagnostic interpretation of the alveolar bone crest.
Abstract
PURPOSE: To develop an artificial intelligence (AI) model capable of certifying whether the quality of the bitewing image is adequate or compromised, as an intermediate tool for the technical analysis prior to the final evaluation of the alveolar bone crest. MATERIALS AND METHODS: A total of 372 bitewing radiographs from a radiographic database were classified by three evaluators into control 186 (standard vertical angulation) and test 186 (offset vertical angulation) groups, forming a consensus gold standard for accuracy with the algorithm classification. The region of interest was defined as the non-overlapping area between the buccal and palatal/lingual cusps for data labeling, using the YOLOv8n-Seg architecture for training, validation, and testing. The model's performance was evaluated by comparing the average areas among groups, computing the metrics of precision, sensitivity, specificity, accuracy, recall and F1 score. RESULTS: The AI model achieved a classification accuracy of 96.7%, with 100% sensitivity and 93.8% specificity (ICC = 0.95). The precision was 0.93, the recall 1.0 and the F1-score 0.96. Across both training and validation stages, significant differences were observed between the test and control groups (P < 0.05), with consistently larger regions of interest areas in the test group. A direct relationship was observed between bitewing radiographs classified as having offset vertical angulation and the regions of interest area. The model achieved excellent accuracy, comparable to that of expert evaluators. CONCLUSION: The AI model accurately segmented and classified whether or not vertical angulation was compromising the quality of bitewing radiographs, thereby minimizing errors in the diagnostic interpretation of the alveolar bone crest.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Keypoint-based detection of periodontal radiographic bone loss on bitewing radiographs using YOLO11-pose: a clinician-AI agreement study.BMC oral health · 2026
- Segmentation-Based Multi-Class Detection and Radiographic Charting of Periodontal and Restorative Conditions on Bitewing Radiographs Using Deep LearningDiagnostics · 2026
- Effectiveness of human-artificial intelligence collaboration for interproximal caries detection using bitewing radiographs: a systematic review.Oral surgery, oral medicine, oral pathology and oral radiology · 2026
- Automated Detection of Positioning Errors in Bitewing Radiographs Using Deep LearningClinical and Experimental Dental Research · 2026
- Human-AI Collaboration in Proximal Early Caries Lesion Detection: Potential Benefits for Novices and Potential Risks for Experts.Caries research · 2026
- AI-assisted radiographic analysis in detecting alveolar bone-loss severity and patternsScientific Reports · 2026