Development of an electroanalytical methodology for the determination of dexamethasone using pencil graphite electrodes
Ellen Soares de Paula, Eliana Maira Agostini Valle, Tiago Luiz Ferreira, Lucia Codognoto
Key points
From the paper's conclusion- These results demonstrate that the proposed method is a simple, cost-effective, and environmentally friendly alternative as a preliminary screening tool for DEX quantification in fortified aqueous matrices, including natural water samples from the Billings Dam.
Abstract
The increasing occurrence of pharmaceutical compounds in aquatic environments has raised concerns about potential impacts on ecosystem integrity and public health. Among these compounds, dexamethasone (DEX), a synthetic glucocorticoid widely used for its anti-inflammatory, antiallergic, and immunosuppressive properties, has attracted attention because of its potential endocrine-disrupting effects and its presence in water bodies. In this work, an electroanalytical method was developed for determining DEX in natural waters using a pencil graphite electrode (PGE). Cyclic voltammetry studies revealed a reduction peak at − 0.93 V vs. Ag/AgCl (3.0 mol L⁻¹ KCl), characteristic of an adsorption-controlled irreversible process, and an oxidation peak at + 0.83 V vs. Ag/AgCl (3.0 mol L⁻¹ KCl), corresponding to a process controlled by diffusion with an adsorption contribution and dependent on the preceding reduction step, possibly referring to the substance generated after the reduction process. Using square-wave voltammetry, linear analytical curves were obtained over the concentration range of 2.00–7.40 µmol L⁻¹. The limits of detection (LOD) and quantification (LOQ) were 0.20 and 0.67 µmol L⁻¹ in ultrapure water (78.5 and 263.0 µg L − 1 ), 0.20 and 0.68 µmol L⁻¹ in tap water (78.5 and 266 µg L − 1 ), and 0.52 and 1.70 µmol L⁻¹ in Billings dam water (204 and 667 µg L − 1 ), respectively. Recovery experiments in dam water yielded 83.7%. These results demonstrate that the proposed method is a simple, cost-effective, and environmentally friendly alternative as a preliminary screening tool for DEX quantification in fortified aqueous matrices, including natural water samples from the Billings Dam.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrochemical detection of carbendazim in food and water samples using a pentapeptide-modified pencil graphite electrodeInternational Journal of Environmental & Analytical Chemistry · 2026
- Differential pulse voltammetric assay of H 1 -antihistamine fexofenadine in pharmaceutical formulations using a bare glassy carbon electrodeActa Chimica Slovaca · 2026
- Ecologically conscious profiles assessments for economic, and concurrent HPLC detection of chlordiazepoxide and clidinium bromide in bulk and tablets solid dosage formResults in Chemistry · 2025
- Determination of Uric Acid in Human Urine by Differential Normal Pulse Voltammetry With a Bare Glassy Carbon ElectrodeElectroanalysis · 2026
- Evaluating Analytical Performance of Commercial Screen-Printed Electrodes for Point-of-Care Uric Acid Sensing: A Comparative StudyApplied Sciences · 2026
- Simultaneous voltammetric determination of triclosan and chlorhexidine in pharmaceutical and personal care products at glassy carbon electrode.Journal of pharmaceutical and biomedical analysis · 2026