Factors associated with successful initiation of labor analgesia using the dural puncture epidural technique: a retrospective cohort study.
Ayaka Kuwabata, Jun Takeshita, Kazuya Tachibana
Department of Anesthesiology, Osaka Prefectural Hospital Organization, Osaka Women's and Children's Hospital, 840 Murodo-cho, Izumi, Osaka, 594-1101, Japan. · Department of Anesthesiology, Osaka Prefectural Hospital Organization, Osaka Women's and Children's Hospital, 840 Murodo-cho, Izumi, Osaka, 594-1101, Japan. t-k-s-t@koto.kpu-m.ac.jp.
Key points
From the paper's conclusion- Operator experience was independently associated with successful initiation of labor analgesia using the DPE technique and was the only factor associated with both procedural success and early analgesic effectiveness. Operator- and patient-related factors should be considered when predicting the likelihood of successful initiation of labor analgesia using the DPE technique.
Abstract
PURPOSE: The dural puncture epidural (DPE) technique has been proposed as a modification of conventional epidural analgesia that may influence onset and block quality. However, factors associated with successful initiation of labor analgesia using the DPE technique remain unclear. We aimed to identify predictors for successful initiation of labor analgesia using the DPE technique. METHODS: This retrospective study included parturients who received DPE for initiation of labor analgesia between April 2022 and March 2025. Success was defined as a composite outcome of epidural catheter placement within 15 min from initial skin puncture with the epidural needle and a numerical rating scale (NRS) pain score ≤ 3 recorded between 30 and 60 min after the first epidural bolus. Multivariable logistic regression was performed to identify independent predictors of success. RESULTS: Among the 1037 parturients included in the analysis, success was achieved in 693 cases, whereas 344 were classified as failures. In the multivariable analysis, operator experience (per 10 procedures) (odds ratio 1.10, 95% confidence interval 1.04 to 1.15, P < 0.001), baseline NRS (P < 0.001), cervical dilation at initiation (P = 0.038), maternal age (P = 0.013), and spinal disorder (P = 0.034) were identified as independent predictors of success. CONCLUSION: Operator experience was independently associated with successful initiation of labor analgesia using the DPE technique and was the only factor associated with both procedural success and early analgesic effectiveness. Operator- and patient-related factors should be considered when predicting the likelihood of successful initiation of labor analgesia using the DPE technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dural Puncture Epidural versus Standard Epidural: A Randomized Double-Blinded Comparison of Optimal Programmed Intermittent Epidural Bolus Intervals for Labor Analgesia.Drug design, development and therapy · 2026
- Effective volume of ropivacaine 0.1% plus sufentanil 0.3 μg·mL-1 for labour epidural analgesia initiation after dural puncture epidural technique: a biased-coin up-and-down sequential allocation study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Association of dural-puncture epidural with conversion of labor analgesia to cesarean delivery anesthesia: a propensity score-weighted retrospective cohort studyBMC Anesthesiology · 2026
- Dural Puncture Epidural, Standard Epidural, and No Epidural: Comparative Effects on Labor Progression and Neonatal Outcomes.Journal of clinical medicine · 2026
- Effective Dose 90 of Programmed Intermittent Epidural Bolus Volume at Three Ropivacaine Concentrations with Dural Puncture Epidural for Labor Analgesia: A Randomized Sequential Allocation Study.Drug design, development and therapy · 2026
- Epidural Analgesia and Its Impact on the Duration of the Second Stage of Labor, Vacuum Extraction Delivery, and Neonatal Apgar Scores: A Retrospective Cohort Study.Medicina (Kaunas, Lithuania) · 2026