Association of dural-puncture epidural with conversion of labor analgesia to cesarean delivery anesthesia: a propensity score-weighted retrospective cohort study
Zhengbin Pan, Jiefeng Chen, Juan Feng, Hao Lv, Yiyu Pan
Key points
From the paper's conclusion- Conclusions In this retrospective cohort of parturients undergoing intrapartum cesarean delivery after labor analgesia, DPE was not associated with a statistically significant difference in the primary outcome of conversion failure.
Abstract
Background Extension of labor epidural analgesia to cesarean delivery anesthesia may fail, requiring a repeat neuraxial procedure or general anesthesia. Trials in elective cesarean delivery suggest that dural-puncture epidural (DPE) can accelerate epidural extension, but evidence after established labor analgesia remains limited. Methods This single-center retrospective cohort study included singleton parturients who underwent intrapartum cesarean delivery after labor analgesia between September 2023 and April 2026. Patients were classified according to labor analgesia technique: DPE or conventional epidural. Inverse probability of treatment weighting (IPTW) based on the propensity score was used to balance baseline covariates. The primary outcome was conversion failure, defined as the requirement for a repeat neuraxial procedure or conversion to general anesthesia. Secondary outcomes included anesthesia onset time, intraoperative pain, block characteristics, hemodynamic events, and satisfaction scores. Results A total of 521 parturients were analyzed, including 133 in the DPE group and 388 in the conventional epidural group. After IPTW adjustment, covariates in the propensity score model were balanced. Conversion failure occurred in 3 patients (2.3%) in the DPE group and 22 patients (5.7%) in the conventional epidural group (IPTW-weighted OR, 0.36; 95% CI, 0.11–1.22; P = 0.101). In a secondary analysis, anesthesia onset time was shorter in the DPE group (15.05 ± 1.47 min vs. 15.80 ± 1.55 min; IPTW-weighted β, -0.77 min; 95% CI, -1.07 to -0.47; P < 0.001). Estimates for other perioperative outcomes were imprecise and their confidence intervals included the null. Sensitivity analyses for conversion failure produced similar point estimates, with all confidence intervals crossing unity. Conclusions In this retrospective cohort of parturients undergoing intrapartum cesarean delivery after labor analgesia, DPE was not associated with a statistically significant difference in the primary outcome of conversion failure. A secondary analysis found an approximately 0.8-minute shorter onset of surgical anesthesia with DPE, although the clinical importance of this small difference remains uncertain. These findings provide real-world observational evidence on epidural conversion performance after established labor analgesia and can inform both clinical practice and the design of future prospective studies. Trial registration Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dural Puncture Epidural, Standard Epidural, and No Epidural: Comparative Effects on Labor Progression and Neonatal Outcomes.Journal of clinical medicine · 2026
- Dural Puncture Epidural versus Standard Epidural: A Randomized Double-Blinded Comparison of Optimal Programmed Intermittent Epidural Bolus Intervals for Labor Analgesia.Drug design, development and therapy · 2026
- Association between prior epidural labour analgesia and increased incidence of hypotension after spinal anaesthesia for caesarean section: A retrospective propensity score-matched cohort study.Anaesthesia and intensive care · 2026
- Association of patient and clinical characteristics with failed conversion of neuraxial anesthesia for intrapartum cesarean delivery among patients who had top-up of indwelling labor epidural catheters: a retrospective single center study.Proceedings (Baylor University. Medical Center) · 2026
- Association between epidural analgesia in the second delivery among women with a prior epidural and maternal and neonatal outcomes: a retrospective cohort study.BMC pregnancy and childbirth · 2026
- Factors associated with successful initiation of labor analgesia using the dural puncture epidural technique: a retrospective cohort study.Journal of anesthesia · 2026