Effective Dose 90 of Programmed Intermittent Epidural Bolus Volume at Three Ropivacaine Concentrations with Dural Puncture Epidural for Labor Analgesia: A Randomized Sequential Allocation Study.
Linsen Sun, Xiaojuan Ding, Peng Zhai, Yan Jiang, Meijuan Sun, Xiangsheng Xiong
Department of Anesthesiology, Huai'an Hospital Affiliated to Yangzhou University (The Fifth People's Hospital of Huai'an), Huaian, People's Republic of China.
Key points
From the paper's conclusion- When the combined DPE and PIEB technique is applied for effective labor analgesia, the ED90 of PIEB volume at concentrations of 0.075%, 0.1%, and 0.125% is 13.2 mL, 11.1 mL, and 9.4 mL respectively. Since higher concentration corresponds to a higher administered dose of ropivacaine, the ED90 of PIEB volume decreases as concentration increases.
Abstract
BACKGROUND: This study aimed to explore the ED90 of programmed intermittent epidural bolus (PIEB) volume for labor analgesia with different concentrations of ropivacaine when combining with dural puncture epidural (DPE) techniques. METHODS: Ninety patients were randomized to three groups (n=30 each) to receive an initial 12-mL bolus of ropivacaine (0.075%, 0.1%, or 0.125%) with 0.3 μg/mL sufentanil. PIEB began at 60 min after the initial bolus, with 45-min intervals; the first patient in each group received 10 mL ropivacaine‑sufentanil solution, and subsequent volumes were adjusted by ± 2 mL via sequential allocation based on effective labor analgesia (no epidural bolus intervention administered). The primary and secondary outcomes were, respectively, the ED90 of PIEB volume at different ropivacaine concentrations for effective labor analgesia, and maternal analgesia quality and neonatal outcomes. RESULTS: The ED90 of PIEB volume for achieving effective labor analgesia was 13.2 mL (95% CI, 11.9-14.5), 11.1 mL (95% CI, 10.0-12.2), and 9.4 mL (95% CI, 8.4-10.3) in the 0.075%, 0.1%, and 0.125% groups, respectively. No statistically significant differences in maternal analgesia quality and neonatal outcomes were identified among groups. CONCLUSION: When the combined DPE and PIEB technique is applied for effective labor analgesia, the ED90 of PIEB volume at concentrations of 0.075%, 0.1%, and 0.125% is 13.2 mL, 11.1 mL, and 9.4 mL respectively. Since higher concentration corresponds to a higher administered dose of ropivacaine, the ED90 of PIEB volume decreases as concentration increases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effective volume of ropivacaine 0.1% plus sufentanil 0.3 μg·mL-1 for labour epidural analgesia initiation after dural puncture epidural technique: a biased-coin up-and-down sequential allocation study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Dural Puncture Epidural versus Standard Epidural: A Randomized Double-Blinded Comparison of Optimal Programmed Intermittent Epidural Bolus Intervals for Labor Analgesia.Drug design, development and therapy · 2026
- Determination of the ED50 and ED95 of intrathecal ropivacaine for labor analgesia in multiparous women: A prospective, sequential allocation study.Medicine · 2026
- Epidural maintenance strategies and second-stage feedback interventions during labour analgesia: a pairwise meta-analysis and narrative synthesis.Journal of anesthesia, analgesia and critical care · 2026
- Management of breakthrough pain during advanced labor with epidural alkalinized lidocaine 0.3%-epinephrine: a single-center retrospective study (2022-2026).International journal of obstetric anesthesia · 2026
- Comparison of 0.1% Ropivacaine and 0.0625% Bupivacaine With Fentanyl as an Adjuvant for Labour Analgesia.Cureus · 2026