Augmented reality for robotic surgery: a feasibility study and comparison of registration algorithms for robot-assisted minimally invasive esophagectomy (RAMIE).

G M Kuiper, J van der Duin, R L P D de Jong, Y Li, R C van Jaarsveld, F Badaloni, K Gogoladze, R van Hillegersberg,

Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. g.m.kuiper-2@umcutrecht.nl. · Department of Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.

Key points

From the paper's conclusion
  • This feasibility study shows that image-to-patient registration for augmented reality in RAMIE is technically achievable using real clinical data. Manual registration provides the highest robustness, while fully automated global methods remain limited under intraoperative conditions. Achieved registration accuracies in accepted cases may support basic anatomical orientation but require further development, particularly in deformable registration and intraoperative reconstruction, before reliable intraoperative AR guidance becomes feasible.

Abstract

BACKGROUND: Intraoperative augmented reality (AR) guidance could improve surgical orientation in robot-assisted minimally invasive esophagectomy (RAMIE), but reliable image-to-patient registration between preoperative imaging and the intraoperative scene remains a key technical barrier. This feasibility study aimed to explore the potential of AR for RAMIE and to establish a foundation for intraoperative AR guidance by systematically comparing image-to-patient registration methods using real-world clinical data. METHODS: In this feasibility study, ten consecutive patients undergoing RAMIE were included. Preoperative 3D anatomical models were generated from CT scans using semi-automated segmentation. Intraoperative 3D point clouds were reconstructed from stereoscopic robotic surgical video using stereo-based depth estimation. One manual and six fully automated image-to-patient registration methods were evaluated: Go-ICP, AFWA, CPD, RANSAC, Super4PCS, and FMR. The azygos vein was used as the registration landmark, and registration performance was assessed by qualitative acceptance rate and surface-to-surface distance using the trachea as an independent evaluation structure. RESULTS: Manual registration achieved a success rate of 0.80, with a mean surface distance (MSD) of 11.46 mm, Hausdorff distance (HD) of 15.20 mm, and a mean computation time of 22.73 s. Among automated methods, success rates ranged from 0.10 (AFWA, FMR) to 0.40 (Super4PCS). All automated methods completed registration in under 3 s. Surface distances were based on one to eight accepted registrations per method and did not reliably distinguish accepted from rejected registrations. CONCLUSION: This feasibility study shows that image-to-patient registration for augmented reality in RAMIE is technically achievable using real clinical data. Manual registration provides the highest robustness, while fully automated global methods remain limited under intraoperative conditions. Achieved registration accuracies in accepted cases may support basic anatomical orientation but require further development, particularly in deformable registration and intraoperative reconstruction, before reliable intraoperative AR guidance becomes feasible.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers