Automatic cochlear morphometry: intraindividual comparison of head CT vs carotid CT angiography, cervical spine, and paranasal sinus CT.
Henner Huflage, Maria Reder, Bjoern Spahn, Philipp Feldle, Stephan Hackenberg, Mirko Pham, Thorsten Alexander Bley, Kristen Rak,
Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany. Huflage_H@ukw.de. · Department of Oto-Rhino-Laryngology, Head and Neck Surgery, University Hospital Würzburg, Würzburg, Germany.
Key points
From the paper's conclusion- Despite lower CNR, CDL measurements based on cervical spine, carotid artery, and paranasal sinus CT yield comparable results to head CT imaging, suggesting potential for considerable dose reduction in cochlear morphometry.
Abstract
PURPOSE: In cochlear implantation, precise estimation of cochlear duct length (CDL) is essential for individualized electrode array selection. This study provides an intraindividual comparison of CDL measurements based on head CT vs cervical spine, carotid artery, and paranasal sinus imaging. MATERIALS AND METHODS: For this retrospective investigation, automatic CDL measurements focused on the organ of Corti were performed in 459 patients (70.7 ± 17.8 years, 240 women), who underwent both head CT (120 kVp) and either cervical spine CT (Sn 150 kVp, 293 patients), carotid CT angiography (100 kVp, 133 patients), or paranasal sinus CT (Sn 100 kVp, 33 patients). Additionally, radiation dose and contrast-to-noise ratios were compared. RESULTS: Head CT (median 53.2 [interquartile range 49.6-56.8] mGy) was associated with a higher CTDIvol than cervical spine (16.3 [15.6-16.9] mGy), carotid artery (8.4 [8.2-8.7] mGy), and paranasal sinus CT (fixed 5.0 mGy; p < 0.001). CNR was higher in head CT (24.3 [21.4-27.1]) compared with carotid artery (17.9 [15.3-20.6]), cervical spine (12.3 [10.9-13.6]), and paranasal sinus CT (6.6 [5.7-7.4]; p < 0.001). No intraindividual CDL difference was ascertained for head CT (35.5 [34.4-36.5] mm) vs cervical spine (35.5 [34.3-36.5] mm; p = 0.371) and paranasal sinus CT (35.0 [34.3-36.1] mm; p = 0.112), whereas a small, but statistically significant difference, was found in the carotid artery sample (35.4 [34.4-36.4] mm; p < 0.001). CONCLUSION: Despite lower CNR, CDL measurements based on cervical spine, carotid artery, and paranasal sinus CT yield comparable results to head CT imaging, suggesting potential for considerable dose reduction in cochlear morphometry. KEY POINTS: Question Do technically diverse low-dose protocols covering the temporal bone provide robust automatic CDL measurements in a large real-world patient sample? Findings In 459 patients, automatic cochlear morphometry from carotid angiography, cervical spine, and paranasal sinus CT was intraindividually comparable to head CT, despite lower CNR. Clinical relevance Validation of automatic CDL measurements from various routine CT protocols covering the temporal bone enables opportunistic cochlear implant planning with substantially reduced radiation exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anatomical characteristics of the human cochlea in Bahrain.Acta oto-laryngologica · 2026
- Application Value of Cochlear Size Assessment in Cochlear Implantation Surgery.The journal of international advanced otology · 2026
- Feasibility of Ultra-Low-Dose Photon-Counting CT for Anatomy-Based Cochlear Implant Fitting: A Cadaveric Proof-of-Concept Study.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Improved assessment of the cochlear implant and temporal bone structures with ultra-high resolution photon-counting detector CT compared to conventional CT systems.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Comparative analysis of cochlear duct length using computed tomography in South Indian and Scottish populations: Implications for cochlear implant electrode selection.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Photon-counting detector CT versus cone-beam CT for postoperative cochlear implant imaging.European journal of radiology · 2026