Finite element analysis of different subtrochanteric osteotomy techniques in total hip arthroplasty for high hip dislocation.
Weilong Diwu, Huifa Xu, Qi Wu, Yuanqi Hong, Bingchen Xia, Yisheng Han, Long Bi, Zhong Wang,
Department of Orthopedics, Xijing Hospital of The Fourth Military Medical University, Xi'an, China. · Department of Orthopedics, Honghui Hospital of the Xi'an Jiaotong University, Xi'an, China.
Key points
From the paper's conclusion- No single osteotomy technique outperformed others in all metrics. The z-shaped and -90° designs offered the best rotational stability; the -90° and 90° designs minimized axial separation; the 45° model showed the worst 'windshield wiper' effect. The 120° technique provided a balanced profile with moderate rotational stability, acceptable separation, and less pronounced stress rings, representing a reasonable compromise. The choice should be guided by clinical priorities.
Abstract
AIMS: Subtrochanteric shortening osteotomy in total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) has variable outcomes. This study evaluated the initial stability of seven different osteotomy techniques. METHODS: A 3D finite element model of a femur with a stem was created. Seven models simulating osteotomies with different angles (0°, 45°, 90°, -90°, 120°, -120°, z-shaped) were analyzed. Outcomes included range of motion (ROM), bone/implant stress, and osteotomy surface separation. RESULTS: The 0° model had the greatest ROM (lowest stiffness). The z-shaped and -90° designs provided the best rotational stability. Analysis of the centre of rotation showed single-symmetric models (45°, z-shaped) shifted laterally, suggesting a 'windshield wiper' effect, while double-symmetric models (90°, -90°, 120°, -120°) stayed aligned with the prosthesis axis. Stress patterns differed: single-symmetric models concentrated stress on the lesser trochanter, while double-symmetric models stressed the greater trochanter, with a notable ring in the -90° design. Implant stresses were similar, except in the horizontal model. The -90° and 90° models had the least osteotomy separation, unlike the 45° model. CONCLUSION: No single osteotomy technique outperformed others in all metrics. The z-shaped and -90° designs offered the best rotational stability; the -90° and 90° designs minimized axial separation; the 45° model showed the worst 'windshield wiper' effect. The 120° technique provided a balanced profile with moderate rotational stability, acceptable separation, and less pronounced stress rings, representing a reasonable compromise. The choice should be guided by clinical priorities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Femoral Shortening Osteotomy Techniques in Total Hip Arthroplasty for Hartofilakidis Type C Developmental Hip Dysplasia: A 25-Year Single-Surgeon Series.The Journal of arthroplasty · 2026
- Preoperative factors associated with alignment change from planned metaphyseal- to diaphyseal-dominant fixation in calcar-guided short-stem total hip arthroplasty.International orthopaedics · 2026
- Crowe severity and femoral stem geometry are associated with lower-limb alignment after total hip arthroplasty for unilateral developmental dysplasia of the hip-related secondary osteoarthritis: valgus alignment trajectories.Archives of orthopaedic and trauma surgery · 2026
- Influence of stem undersizing during direct anterior approach for total hip arthroplasty on periprosthetic bone biomechanics : a finite element analysis.Bone & joint research · 2026
- Range of motion simulated with patient-specific three-dimensional simulation analysis for evaluating anterior dislocation after total hip arthroplasty.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- EP1.95 Finite element analysis of PAO bone scaffold design and biomechanical effectsJournal of Hip Preservation Surgery · 2026