International orthopaedics

Effect of native Posterior condylar axis-Transepicondylar axis variability on femoral component rotation using robotic total knee arthroplasty.

Prashant Tank, Nitin Chauhan, Harsh Jain, Tejaswin Jha, Vivek Shankar, Vijay Kumar

All India Institute of Medical Sciences, New Delhi, India. prashanttank12@gmail.com. · All India Institute of Medical Sciences, New Delhi, India.

Observational · n=52

Key points

From the paper's conclusion
  • Robotic functional alignment adapts femoral component rotation to native PCA-TEA anatomy within predefined rotational boundaries rather than adhering to a fixed 3° paradigm. While this demonstrates patient-specific rotational adaptation, whether such adaptation provides a clinical benefit remains to be demonstrated.

Abstract

PURPOSE: Accurate femoral component rotation in total knee arthroplasty (TKA) is critical for flexion balance, patellofemoral tracking, and implant longevity. Conventional techniques apply a fixed 3° external rotation relative to the posterior condylar axis (PCA), assuming a constant relationship with the transepicondylar axis (TEA). However, anatomical variability challenges this assumption. This study evaluated whether robotic-assisted TKA individualizes femoral rotation according to native PCA-TEA anatomy rather than applying a fixed rotational target. MATERIALS AND METHODS: This retrospective study included 52 patients (72 knees) undergoing primary CT-based robot (MAKO) assisted TKA for primary osteoarthritis of the knee. Preoperative CT scans were used to determine the native PCA-TEA angle. Intraoperative femoral component rotation relative to PCA and TEA was recorded using robot-generated measurements. Correlations were assessed using Spearman's coefficient, with subgroup analysis across PCA-TEA strata. RESULTS: The median PCA-TEA angle was 2.3° (range -1.9 to 8.7°). Median femoral rotation was 3.9° (range -1.2 to 9.6°) relative to PCA and 1.1° (range -3.4 to 4.9°) relative to TEA. A strong positive correlation existed between PCA-TEA angle and rotation relative to PCA (ρ = 0.8, p < 0.001), while a moderate negative correlation was observed relative to TEA (ρ = -0.5, p < 0.001). Knees with negative PCA-TEA anatomy demonstrated significantly lower rotation than the conventional 3° target (p < 0.05). CONCLUSION: Robotic functional alignment adapts femoral component rotation to native PCA-TEA anatomy within predefined rotational boundaries rather than adhering to a fixed 3° paradigm. While this demonstrates patient-specific rotational adaptation, whether such adaptation provides a clinical benefit remains to be demonstrated.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers