Robotic-assisted versus sensor-guided total knee arthroplasty for severe varus or valgus deformities
Tihui Wang, Hui Wang, Zhenbao Lu, Hongwei Xu, Jinqing Wu, Xu Wang
Key points
From the paper's conclusion- Objective To compare the clinical and radiographic outcomes of robotic-assisted total knee arthroplasty (r-TKA) with those of sensor-guided total knee arthroplasty (s-TKA) in patients with severe varus or valgus deformities.
Abstract
Objective To compare the clinical and radiographic outcomes of robotic-assisted total knee arthroplasty (r-TKA) with those of sensor-guided total knee arthroplasty (s-TKA) in patients with severe varus or valgus deformities. Methods This retrospective study enrolled 76 patients with symptomatic knee arthritis with severe varus or valgus deformity, who were assigned to undergo r-TKA ( n = 38) or s-TKA ( n = 38) between May 2024 and May 2025. Radiological parameters included the lateral femoral component (LFC) angle, lateral tibial component (LTC) angle, frontal femoral component (FFC) angle, frontal tibial component (FTC) angle, and hip–knee–ankle (HKA) angle. Data on operative time, visible blood loss volume (VBL), flexion range when walking (FRW), straight-leg raise (SLR) and complications were extracted from patient records. Visual analogue scale at rest and in motion (rVAS, mVAS) scores, passive and active range of motion (pROM, aROM), Western Ontario and McMaster Universities Arthritis Index (WOMAC [stiffness, pain, and function]) scores and Knee Society Score (KSS) were recorded at 1, 3, and 12-months postoperatively. Results The r-TKA group has demonstrated significantly smaller absolute deviations from the target for both HKA and LTC angles, and a higher proportion of knees achieving alignment within ± 3° of the target ( p < 0.05). While no significant intergroup difference was observed in WOMAC stiffness score or pROM, the r-TKA group has demonstrated significantly better aROM and FRW throughout the trial ( p < 0.05). At 3-month and 1-year follow-up, the r-TKA group has shown higher KSS and WOMAC function scores, respectively, than the s-TKA group ( p < 0.05). Postoperatively, no patients in either group required manipulation under anaesthesia (MUA). At 1 year, complication rates and revision-free status were comparable between the groups, with no revisions performed in either group. Conclusion Both techniques have yielded satisfactory short-term outcomes in knees with severe varus or valgus deformities. Compared with s-TKA, r-TKA has provided more precise coronal alignment of lower-limb and superior sagittal component positioning; as well as better functional recovery, as reflected by KSS, WOMAC function score, aROM, FRW and SLR. GRADE evidence level Low.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of the clinical efficacy of robot-assisted left total knee arthroplasty performed by surgeons with varying levels of experienceJournal of Robotic Surgery · 2026
- Imageless robotic assistance versus laser-projected mechanical-axis guidance in total knee arthroplasty: a deformity-stratified comparative cohort study.Journal of robotic surgery · 2026
- Improved precision and Reduced Technical Errors in Total Knee Arthroplasty Using the Velys Robotic-Assisted Solution: Single-Center Comparative Study.Acta orthopaedica Belgica · 2026
- Robotic-assisted total knee arthroplasty: radiological precision, clinical outcomes, and benchmarks for emerging systems.Journal of robotic surgery · 2026
- Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective AnalysisLife · 2026
- Robotic-assisted total knee arthroplasty: accuracy, clinical outcomes, complications, learning curve and cost-effectiveness: a critical clinical review.Journal of robotic surgery · 2026