Femoral rotation and medial flexion gap tightness in functional alignment robotic total knee arthroplasty for varus knees
Eduardo Frois Temponi, Pedro Henrique Oliveira Gomes, Alexandre Leite de Andrade, Miguel Jourdain Alipio do Vale, Matheus Braga Jacques Soares, Luiz Fernando Machado Soares, Lúcio Honório de Carvalho
Pontifícia Universidade Católica de Minas Gerais · Hospital Madre Teresa
Key points
From the paper's conclusion- Greater medial flexion tightness was associated with greater selected femoral rotation.
Abstract
Functional-alignment (FA) robotic total knee arthroplasty (TKA) combines component positioning and soft-tissue management. This study described the association between medial flexion-gap tightness and surgeon-selected femoral rotation, together with release grades and intraoperative gap asymmetry in varus knees. This observational single-surgeon study included the 65 varus knees in an 89-knee database. Medial tightness was defined as lateral minus medial preoperative flexion gap. Correlation and ordinary least-squares regression used 63 complete observations. Recorded preoperative, planned and final trial gaps were analysed with endpoint-specific denominators. An exploratory model considered tibial coronal positioning and posterior slope. Selected rotation was associated with medial tightness (Spearman ρ = 0.571; p < 0.001). The univariable fit was rotation = 1.93° + 0.343°/mm × tightness (R² = 0.257; slope 95% CI, 0.194-0.492). The adjusted slope was 0.296°/mm (95% CI, 0.131-0.460; n = 60). Release was mild in 64/65 and moderate in 1/65 knees. Mean absolute final asymmetry was 0.38 mm in extension and 0.29 mm in flexion. Asymmetry <1 mm occurred in 50/60 (83.3%) and 55/59 (93.2%), respectively; 53/58 (91.4%) met ≤1 mm in both positions. Greater medial flexion tightness was associated with greater selected femoral rotation. Predominantly mild release and small final mean asymmetry accompanied the combined workflow. The equation describes one surgeon's decisions and is not a validated surgical rule. These observations do not establish an independent release-sparing effect, clinical superiority of submillimetre symmetry, patellofemoral safety or long-term benefit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Greater valgus severity is associated with larger lateral flexion-gap changes between intraoperative assessments during robot-assisted total knee arthroplasty: A retrospective cohort study.Journal of experimental orthopaedics · 2026
- The anatomical origin of varus predicts the pattern of intraoperative gap imbalance and the correction required to balance the knee in robotic-assisted total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026
- Kinematical-aligning of femoral component decreases overstuffing of lateral distal condyle and provides better patellar tracking and postoperative outcomes in robotic-assisted total knee arthroplasty.Journal of robotic surgery · 2026
- Functional versus mechanical alignment in robotic primary total knee arthroplasty: A meta-analysis.SICOT-J · 2026
- Functional versus mechanical alignment in robotic primary total knee arthroplasty: A meta-analysis.SICOT-J · 2026
- Robotic-assisted versus sensor-guided total knee arthroplasty for severe varus or valgus deformitiesJournal of Orthopaedic Surgery and Research · 2026