Robust visualization of the right adrenal vein using photon-counting CT across all BMI groups.

Meng Xu, Lan Liu, Rao Song, Haiping Zhang, Xiaojing He, Xiaojing Zhang, Chuanjun Zhong, Dajing Guo,

The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. · Siemens (China), Shanghai, China.

Key points

From the paper's conclusion
  • PCCT provides favorable RAV visualization across the investigated BMI groups, with low-keV imaging and smoother reconstruction kernels associated with improved visualization quality.

Abstract

OBJECTIVE: To evaluate the robust visualization of photon-counting CT (PCCT) for right adrenal vein (RAV) across body mass index (BMI) groups with respect to virtual monochromatic imaging (VMI) energy levels and reconstruction kernels. METHODS: A total of 302 patients who underwent contrast-enhanced abdominal PCCT were enrolled and stratified into non-obese, overweight, and obese groups based on Asian-specific BMI criteria. VMIs were reconstructed at 40, 55, and 70 keV with three vascular‑specific reconstruction kernels (Bv40, Bv48, Bv60). For quantitative evaluation, two radiologists assessed image metrics, including CT attenuation, image noise (standard deviation [SD]), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Separately, another pair of radiologists independently evaluated qualitative image quality (encompassing both overall image quality and RAV visualization quality) using a 5-point Likert scale. RESULTS: Quantitative evaluation showed that VMI energy level and reconstruction kernel were associated with changes in quantitative image quality metrics, with significant interactions between energy level and reconstruction kernel for all four quantitative metrics (all P < 0.001). Exploratory analyses suggested BMI-related interactions in RAV attenuation and subjective visualization quality. Lower keV increased RAV CT attenuation and CNR, with the highest values at 40 keV across all BMI groups. Qualitative evaluation demonstrated a 100% RAV visualization rate across all reconstruction settings and BMI groups, with median visualization scores ranging from 3.0 to 5.0. Inter-reader agreement was excellent (weighted κ = 0.82). CONCLUSION: PCCT provides favorable RAV visualization across the investigated BMI groups, with low-keV imaging and smoother reconstruction kernels associated with improved visualization quality.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Robust visualization of the right adrenal vein using photon-counting CT across all BMI groups — Science Skim