When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation.
Alisa Mohebbi, Mohammad Mirza-Aghazadeh-Attari, Zahra Moradi, Ali Abbasian Ardakani, Afshin Mohammadi
Tehran University of Medical Sciences, Tehran, Islamic Republic of Iran. · Johns Hopkins Medicine, Baltimore, USA.
Key points
From the paper's conclusion- In this study, pre-HIFU US-MRI discordance was not associated with clear differences in technical success, technical efficacy, adverse events, or short-term procedural outcomes. Recognition of discordance may still help inform procedural planning and patient counseling within SIR-standardized frameworks.
Abstract
PURPOSE: To evaluate the prevalence of pre-procedural US-MRI discordance and its association with Society of Interventional Radiology (SIR)-standardized outcomes in patients undergoing US-guided high-intensity focused ultrasound (HIFU) ablation for symptomatic uterine fibroids. MATERIALS AND METHODS: 308 consecutive patients were included. Discordance was defined as mismatch in fibroid type, location, uterine position, or absolute volume percentage difference > 50%. Patients were stratified into concordant (n = 252) and discordant (n = 56) groups. Outcomes were assessed according to SIR domains: technical success (non-perfused volume ratio on day-1 contrast-enhanced MRI), technical efficacy (through six procedural surrogates as a whole: energy-efficiency factor, overall treatment time, cumulative sonication time, treatment intensity, average sonication power, and oxytocin dose), adverse events (SIR classification), and favorable short-term procedural outcome. RESULTS: Discordance occurred in 18.2% of cases. Categorical agreement was high, with Gwet's AC1 > 0.93, and volume agreement was good, with an intraclass correlation coefficient of 0.773. Day-1 non-perfused volume ratio and technical-success thresholds were comparable between groups. In unadjusted analysis, the energy-efficiency factor was higher after discordant imaging (p = 0.024) and oxytocin use was shifted toward the 60 IU dose (p = 0.036). After adjustment, neither association remained significant (p = 0.191 and 0.228). Adverse-event profiles and the favorable short-term procedural outcome did not differ significantly. CONCLUSION: In this study, pre-HIFU US-MRI discordance was not associated with clear differences in technical success, technical efficacy, adverse events, or short-term procedural outcomes. Recognition of discordance may still help inform procedural planning and patient counseling within SIR-standardized frameworks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRI-Based Analysis of Post-HIFU Efficacy in Uterine Adenomyosis and Personalized Treatment Strategies.Gynecologic and obstetric investigation · 2026
- Development and internal validation of a nomogram based on MRI and clinical features for predicting high ablation difficulty in ultrasound-guided HIFU for adenomyosisFrontiers in Medicine · 2026
- Concordance of Preoperative Transvaginal Ultrasound and Intraoperative Findings in Fibroid Ablation Using Transcervical UltrasoundJournal of Ultrasound in Medicine · 2026
- Coagulation function changes after high-intensity focused ultrasound therapy for uterine fibroids and adenomyosis: a large retrospective cohort studyInternational Journal of Hyperthermia · 2026
- Deep Learning-Based Gadolinium-Free Virtual Contrast-Enhanced MRI for Predicting Immediate HIFU Ablation Outcomes in Uterine Fibroids.Academic radiology · 2026
- Impact of Hemoglobin Levels on Therapeutic Efficacy and Energy Dosage in Ultrasound‐Guided HIFU Ablation of Uterine FibroidsJournal of Ultrasound in Medicine · 2026