Coagulation function changes after high-intensity focused ultrasound therapy for uterine fibroids and adenomyosis: a large retrospective cohort study
Xiaofei Zhang, Jingyi Ni, Weiwei Xu, Ruomeng Bi, Yingying Yang, Xinhua Yang, Bin Lin, Hui Li,
Shanghai First Maternity and Infant Hospital · Hong Kong Baptist University
Key points
From the paper's conclusion- Higher exposure energy during HIFU treatment may induce alterations in coagulation function, resulting in a transient post-treatment hypercoagulable state.
Abstract
OBJECTIVE: High-intensity focused ultrasound (HIFU) therapy is increasingly used in the management of various solid tumors. However, limited data are available regarding the association between HIFU treatment and coagulation function. MATERIALS AND METHODS: A total of 1,189 patients diagnosed with uterine fibroids or adenomyosis who underwent HIFU therapy at Shanghai First Maternal and Infant Hospital between August 2015 and November 2020 were included. Paired t-tests were conducted to compare coagulation indicators measured before and after HIFU treatment. Multiple logistic regression models were used to calculate adjusted odds ratios (ORs) and 95% confidence intervals (CIs) to evaluate the association between the risk of elevated D-dimer/fibrinogen degradation products (FDP) and HIFU treatment parameters categorized into tertiles. RESULTS: A total of 1,148 eligible patients were included in the final analysis. After HIFU treatment, 61.8% and 55.7% of patients showed elevated D-dimer and FDP levels, respectively, and 54.6% exhibited simultaneous elevation of both on the first day after treatment. Other post-treatment coagulation indicators also demonstrated a hypercoagulable state, including prolonged prothrombin time and thrombin time, shortened activated partial thromboplastin time, and decreased platelet count. During follow-up, no patients developed thromboembolism. Several HIFU parameters were associated with increased D-dimer and FDP levels. The highest tertile of exposure energy was significantly associated with a greater risk of simultaneous elevation of both D-dimer and FDP (adjusted OR [95% CI]: 4.58 [3.17, 6.66]). CONCLUSION: Higher exposure energy during HIFU treatment may induce alterations in coagulation function, resulting in a transient post-treatment hypercoagulable state.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Impact of High Intensity Focused Ultrasound on Ovarian Reserve in Women with Uterine Fibroids and Adenomyosis: A Systematic Review and Single Arm Meta-Analysis.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Impact of Hemoglobin Levels on Therapeutic Efficacy and Energy Dosage in Ultrasound‐Guided HIFU Ablation of Uterine FibroidsJournal of Ultrasound in Medicine · 2026
- MRI-Based Analysis of Post-HIFU Efficacy in Uterine Adenomyosis and Personalized Treatment Strategies.Gynecologic and obstetric investigation · 2026
- When US and MRI disagree: association of pre- high-intensity focused ultrasound imaging discordance with technical, safety, and clinical outcomes in uterine fibroid ablation.Abdominal radiology (New York) · 2026
- Development and internal validation of a nomogram based on MRI and clinical features for predicting high ablation difficulty in ultrasound-guided HIFU for adenomyosisFrontiers in Medicine · 2026
- Ultrasound Imaging: A Cornerstone of the Entire High-Intensity Focused Ultrasound Tumor Treatment Continuum.Diagnostics (Basel, Switzerland) · 2026