Combining Clinical LAFOV PET/CT with a Digital Twin Providing Motion-Free Ground Truth Reveals Quantitative Trade-offs in Respiratory Motion Correction
W. Lan, S. Weigel, E. Calderon, C. l. Fougere, F. P. Schmidt
Key points
From the paper's conclusion- Conclusion: Combining clinical PET with a realistic digital twin and corresponding motion-free ground truth enabled objective validation of respiratory MoCo beyond conventional clinical evaluation.
Abstract
Purpose: Respiratory motion remains a major source of quantitative bias in PET and becomes increasingly relevant for high-sensitivity long axial field-of-view (LAFOV) PET/CT. Although numerous respiratory motion correction (MoCo) methods have been proposed, their quantitative accuracy cannot be established clinically because a patient-specific motion-free reference is fundamentally unavailable in vivo. This study combined clinical PET imaging with a digital twin, a realistic representation of both the PET/CT system and the patient, to objectively validate respiratory MoCo against a corresponding motion-free reference. Methods: Twenty patients (10 [18F]FDG with predominantly pulmonary lesions and 10 [18F]SiFAlin-TATE with predominantly hepatic lesions; total 135 lesions) were analyzed. The digital twin combined a validated LAFOV PET/CT simulation model with an anatomically realistic phantom containing 14 lung and liver lesions, two patient-derived respiratory patterns, and respiratory motion amplitudes of 2 and 3 cm, generating patient-like datasets with corresponding motion-free references. Data-driven and image-based MoCo were evaluated using lesion morphology, SUVmean, SUVmax, and metabolic tumor volume (MTV). Results: In patients, data-driven MoCo produced larger SUVmean increases than image-based MoCo for liver (48.1{+/-}18.9% vs. 17.0 {+/-} 12.0%; p<0.01), lower-lung (32.5{+/-}21.2% vs. 16.3{+/-}15.6%, p=0.06), and upper-lung lesions (28.4{+/-}32.0% vs. 10.4 {+/-} 17.2%; p<0.01), with similar findings for SUVmax and larger MTV reductions. Simulation revealed marked motion-induced SUVmean underestimation before correction, particularly in liver (-31.2{+/-}6.8%) and lower lung (-15.5{+/-}13.9%). Relative to the motion-free reference, data-driven MoCo most accurately recovered hepatic uptake (4.3{+/-}11.7% vs. -10.0 {+/-} 9.2%; p=0.01) but overestimated pulmonary uptake (lower lung: 19.8{+/-}16.3% vs. -1.6 {+/-} 10.2%; p=0.02). SUVmax showed the same regional behavior, whereas image-based MoCo yielded MTV estimates closer to the reference. Quantitative recovery was largely independent of respiratory pattern, while larger motion amplitudes mainly affected image-based MoCo. Conclusion: Combining clinical PET with a realistic digital twin and corresponding motion-free ground truth enabled objective validation of respiratory MoCo beyond conventional clinical evaluation. Larger correction-induced quantitative changes should not be equated with greater quantitative accuracy. Instead, MoCo performance was region- and metric-dependent, highlighting the value of ground-truth-based validation for developing and benchmarking respiratory motion correction and quantitative PET on LAFOV PET/CT systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Data-Driven Respiratory Motion Correction in 18F-FDG PET for Cardiac Sarcoidosis: A Location-Dependent Phantom Study.Journal of nuclear medicine technology · 2026
- Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolboxEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- Comparative assessment of respiratory-induced tumor motion using fluoroscopy and four-dimensional CT of solitary pulmonary lesions.Journal of applied clinical medical physics · 2026
- SO(3)-based and structure-guided deformable registration for respiratory motion correction in thoracic PETFrontiers in Physics · 2026
- Digital twins of ex vivo human lungs enable accurate and personalized evaluation of therapeutic efficacyNature Biotechnology · 2026
- Spectral analysis of dynamic long-axial-field-of-view PET studies: a flexible framework for whole-body multi-organ kinetic quantificationPhysics in Medicine & Biology · 2026