Skeletal radiology

Synthetic CT from biplanar radiographs for patellofemoral anatomical assessment: development and validation of an adapted X2CT-GAN model.

Qiqi Lu, Renjie Pan, Jinming Qian, Faming Fang, Hai Hu

Department of Orthopedic Biomechanical Laboratory, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China. · School of Computer Science and Technology, East China Normal University, Shanghai, China.

Observational · n=170

Key points

From the paper's conclusion
  • Radiography-derived sCT demonstrated good agreement with real CT for both quantitative measurements and threshold-based classifications relevant to clinical decision-making in patellofemoral instability. These findings suggest that radiography-derived synthetic CT may represent a promising lower-radiation alternative for anatomical assessment of patellofemoral instability in selected clinical scenarios.

Abstract

OBJECTIVES: Accurate assessment of osseous morphology is essential for the diagnosis and surgical management of patellofemoral instability. Methods capable of providing CT-like anatomical information while reducing radiation exposure are therefore of considerable clinical interest. This study aimed to validate the accuracy of radiography-derived synthetic computed tomography (sCT) generated by a deep learning model for anatomical assessment of patellofemoral instability. METHODS: A total of 210 paired radiographs and CT scans were retrospectively collected and randomly divided into a training set (n = 170) and a validation set (n = 40). A deep learning model based on the X2CT-GAN framework was used to reconstruct sCT volumes from anteroposterior and lateral radiographs. Two blinded readers independently measured tibial tubercle-trochlear groove (TT-TG) distance, trochlear sulcus angle, and Caton-Deschamps index on both sCT and real CT images. Reliability, inter-modality agreement, and threshold-based classification agreement were evaluated. RESULTS: All intra- and inter-observer reliability values were excellent. Inter-modality agreement was excellent for TT-TG distance and good for trochlear sulcus angle. Agreement for patellar height was good. The mean absolute error for TT-TG distance ranged from 1.24 to 1.38 mm. Agreement for threshold-based classifications ranged from substantial to almost perfect, with high specificity observed across all evaluated cutoff values. CONCLUSIONS: Radiography-derived sCT demonstrated good agreement with real CT for both quantitative measurements and threshold-based classifications relevant to clinical decision-making in patellofemoral instability. These findings suggest that radiography-derived synthetic CT may represent a promising lower-radiation alternative for anatomical assessment of patellofemoral instability in selected clinical scenarios.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Synthetic CT from biplanar radiographs for patellofemoral anatomical assessment: development and validation of an adapted X2CT-GAN model — Science Skim