Eliminating Registration Bias in Synthetic CT Generation using a physics-based simulation framework for pelvic anatomy.
Lukas Zimmermann, Michael Rauter, Martin Buschmann, Tatevik Mrva-Ghukasyan, Iustin-Mihai Pirsan, Maximilian Schmid, Dietmar Georg, Barbara Knaeusl
Department of Radiation Oncology, Medical University of Vienna, Spitalgasse 23, Wien, 1090, Austria. · Competence Center for Preclinical Imaging & Biomedical Engineering, University of Applied Sciences Wiener Neustadt, Johannes Gutenberg-Straße 3, Wiener Neustadt, 2700, Austria.
Key points
From the paper's conclusion- We propose physics-based CBCT simulation for geometrically aligned training pairs by construction, with bias-robust geometric metrics.

Approach:A framework simulated pelvic CBCT from fan-beam CT, modeling respiratory motion, X-ray scatter, and noise to yield aligned simulated-CBCT/CT pairs.
Abstract
Supervised synthetic computed tomography (sCT) generation from cone-beam CT (CBCT) requires spatially registered training pairs, yet perfect registration between separately acquired scans is unattainable. This registration bias propagates into trained models and corrupts intensity-based evaluation, so higher benchmark scores may reward reproduction of registration artifacts over anatomical fidelity. We propose physics-based CBCT simulation for geometrically aligned training pairs by construction, with bias-robust geometric metrics. Approach:A framework simulated pelvic CBCT from fan-beam CT, modeling respiratory motion, X-ray scatter, and noise to yield aligned simulated-CBCT/CT pairs. On a clinical gynecological dataset (deformable registration) and the SynthRAD2023 pelvic dataset (rigid registration), sCT models trained on simulated data were compared against models trained on real pairs, a finetuned variant, and CycleGAN and RegGAN baselines. Evaluation combined intensity metrics (MAE, PSNR, SSIM) with geometric alignment metrics (normalized mutual information, NMI; correlation coefficient, CC) against input CBCT. Downstream segmentation of bladder, rectum and bowel bag was assessed in two modes: an sCT cascade applying a CT-trained model to sCT outputs, and direct segmentation by a model trained on simulated CBCT, plus a physics ablation and five-observer quality assessment. Main results:Simulation-trained models achieved higher geometric alignment than real-trained models (cross-dataset NMI 0.31 vs 0.22) despite lower intensity scores. Intensity metrics correlated inversely with observer ratings under deformable registration, whereas NMI consistently predicted clinical preference (clinical ρ = 0.29, SynthRAD ρ = 0.31). Observers preferred simulation-trained outputs in 87% of cases. In the sCT cascade, simulation-trained models improved segmentation (DSC 0.91/0.86/0.54 vs 0.84/0.77/0.04), while direct simulation-trained CBCT segmentation reached 0.92/0.87/0.83, exceeding a phantom-based baseline on the bowel bag. Significance:Physics-based simulation eliminates registration bias at its source, and downstream segmentation provides a task-based measure of sCT conversion quality that intensity metrics miss. Geometric fidelity, not intensity agreement with biased ground truth, aligns with the spatial-accuracy requirements of adaptive radiotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Training-free generation of 4D CT and other rare acquisitions improves segmentation across modalitiesmedRxiv · 2026
- Fidelity-oriented pelvic CBCT-to-CT synthesis using an anatomical information-attention diffusion model.Physical and engineering sciences in medicine · 2026
- Cone-beam CT-based synthetic CT generation for adaptive radiotherapy: methodological paradigms, clinical reliability assessment, and translation.Frontiers in oncology · 2026
- A privacy-preserving federated learning framework for generalizable CBCT to synthetic CT translation in head and neckFrontiers in Digital Health · 2026
- Unsupervised pelvic CBCT-to-CT translation via cross-slice attention for 3D context modeling.Biomedical physics & engineering express · 2026
- Joint-embedding self-supervised representation learning for robust cone-beam CT segmentation.Medical image analysis · 2026