Acute glenoid rim fractures: reliability of linear and surface area methods for CT-based bone loss assessment.
Katarina Lindgren, Lars Adolfsson, Anders Stålman, Erica Domeij-Arverud, Karin Kockum
Karolinska Institutet, Department of Molecular Medicine and Surgery, Karolinska Universitetssjukhuset Solna, Anna Steckséns Gata 53, Stockholm, 171 76, Sweden. katarina.lindgren@ki.se. · Division of Orthopaedic Surgery, Department of Biomedical and Clinical Sciences, Linköping University, Linköping, 581 83, Sweden.
Key points
From the paper's conclusion- Conclusions Linear- and surface area methods demonstrated comparable reliability in assessing glenoid bone loss in acute fractures and we found no difference between 2D- and 3D-modalities.
Abstract
OBJECTIVE: We wanted to investigate and compare the reliability of two measuring methods for glenoid bone loss, one linear- and one surface area method, in acute glenoid fractures after dislocation. This was an experimental study. METHOD: Thirty CT-shoulder scans in patients with an acute glenoid rim fracture were measured in a lateral"en face" view in 2D and 3D by two independent assessors. In 10 of 30 patients contralateral shoulder CT-scan was obtained for reference circle placement. Intra- and interrater reliability was analysed by Intra Class Correlation. Wilcoxon signed rank test was performed for comparison of bone loss estimates between methods. RESULTS: The reliability ranged from 0.85 to 0.97 for the two methods in both 2D and 3D, which is considered good to excellent. The bone loss estimates were significantly larger with linear method than area method. Drawing of a best-fitting-circle had a good reliability between assessors. CONCLUSIONS: Linear- and surface area methods demonstrated comparable reliability in assessing glenoid bone loss in acute fractures and we found no difference between 2D- and 3D-modalities. However, linear methods may overestimate defect in cases with irregular fracture lines, suggesting area method may be preferable in acute fractures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intra- and Interobserver Reliability of the CT-Based Glenoid Arc-Angle Method Using Injured-Side and Contralateral Reference Circles: A Diagnostic Reliability Study.Diagnostics (Basel, Switzerland) · 2026
- Methods for Computed Tomography-Based Glenoid Bone Loss Measurement Show High Interobserver Consistency but Variable Accuracy.Arthroscopy, sports medicine, and rehabilitation · 2026
- CT-based methods for the assessment of glenoid bone loss.Skeletal radiology · 2026
- Comparison of the Reliability and Agreement of Böhler and Gissane Angle Measurements Using PACS and ImageJ.Foot & ankle specialist · 2026
- Reliability of Implant- vs. Bone-Based Postoperative Measurements After Anatomic Total Shoulder Arthroplasty Using CT Imaging.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Magnetic Resonance Imaging Does Not Accurately Estimate the Size of Glenoid Labrum Tears in Patients With Shoulder Instability.Arthroscopy, sports medicine, and rehabilitation · 2026