Comparison of the Reliability and Agreement of Böhler and Gissane Angle Measurements Using PACS and ImageJ.
Rico Te Boekhorst, Jens A Halm, Robert Hemke, Tim Schepers
Trauma Unit, Amsterdam University Medical Center, location AMC, Amsterdam, the Netherlands. · Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, Amsterdam, the Netherlands.
Key points
From the paper's conclusion- This study aimed to define margin of error (MOE) and evaluate whether ImageJ provides measurement agreement and reliability comparable to PACSMethodsMargin of error was predefined based on previously reported variability and expert consensus.
Abstract
BackgroundBöhler's and Gissane's angles are used in calcaneal fracture assessment, but measurement consistency varies. ImageJ may offer a low-cost alternative to Picture Archiving and Communication System (PACS). This study aimed to define margin of error (MOE) and evaluate whether ImageJ provides measurement agreement and reliability comparable to PACSMethodsMargin of error was predefined based on previously reported variability and expert consensus. Three observers measured Böhler's and Gissane's angles on 42 radiographs using PACS and ImageJ; a consensus PACS measurement served as the reference measurement. Reliability (intraclass correlation coefficient), deviation from the consensus reference (mean/median absolute error; bias), agreement within MOE, and Bland-Altman analyses were performed.ResultsThe predefined margins of error were ±2.5° (Böhler) and ±5° (Gissane). Interobserver reliability was good to excellent for Böhler and poor to moderate for Gissane. Within-observer inter-method agreement was excellent for Böhler and variable for Gissane. Deviations for Gissane frequently exceeded the MOE, with minimal method bias.ConclusionImageJ performed comparably to PACS for Böhler's angle measurements. However, Gissane's angle demonstrated poor reproducibility with both methods, likely due to anatomical and projectional factors.Level of evidence:Diagnostic, level III.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calcaneal Morphometry in Children and Adults: Normative Values of the Bohler and Gissane Angles in a Turkish Population.Pakistan journal of medical sciences · 2026
- Intra- and Interobserver Reliability of the CT-Based Glenoid Arc-Angle Method Using Injured-Side and Contralateral Reference Circles: A Diagnostic Reliability Study.Diagnostics (Basel, Switzerland) · 2026
- Acute glenoid rim fractures: reliability of linear and surface area methods for CT-based bone loss assessment.Skeletal radiology · 2026
- From landmark uncertainty to clinical confidence: screening for developmental dysplasia of the hip.Frontiers in medical technology · 2026
- Accuracy and reliability of artificial intelligence-based automated measurement of hallux valgus-related angles on plain foot radiographs: a systematic reviewJournal of Orthopaedic Surgery and Research · 2026
- Methods for Computed Tomography-Based Glenoid Bone Loss Measurement Show High Interobserver Consistency but Variable Accuracy.Arthroscopy, sports medicine, and rehabilitation · 2026