Magnetic Resonance Imaging Does Not Accurately Estimate the Size of Glenoid Labrum Tears in Patients With Shoulder Instability.
Samuel K Gerak, Antonia S Caldwell, William A Crites, Cameron Crasto, Benjamin E Jevnikar, Ronak J Mahatme, Shawn A Moore, Susan E Braley,
College of Medicine University of Cincinnati Cincinnati Ohio U.S.A. · Department of Radiology University of Cincinnati Cincinnati Ohio U.S.A.
Key points
From the paper's conclusion- These findings indicate that MRI may be more appropriately used as a categorical tool for confirming the presence of glenoid labral tears, rather than as a precise measure of tear size.
Abstract
PURPOSE: To compare magnetic resonance imaging (MRI)-based measurements of glenoid labral tears with intraoperative measurements. METHODS: A retrospective review was performed of patients that underwent shoulder capsulorrhaphy between 2019 and 2024 at a single academic medical center. All patients with a single labrum tear, an MRI within 6 months of surgery, and historical tear measurements or measurable intraoperative photographs were included in the study. Glenoid labrum tear size was noted using the clockface convention described in "hours." When clockface measurements were not reported on MRI reads, measurements were made by a radiologist. When clockface measurements were not reported in operative notes, measurements were made by an orthopaedic surgeon using intraoperative photographs. A paired t test was used to evaluate any difference between the MRI and intraoperative measurements. RESULTS: Two hundred sixteen glenoid labral tears from 211 patients met inclusion criteria. Average age was 27.2 ± 11.8 years, 68.5% of patients were men, and 56.9% of glenoid labrum tears were right-sided. On average, MRI measurements exceeded intraoperative measurements (4.15 ± 2.90 hours vs 2.80 ± 1.59 hours) with an average difference of 1.36 ± 3.09 hours (95% confidence interval = 0.94-1.77, P < .001) and a correlation of 0.154 (P = .023). A greater difference in measurement was observed among men compared with women (1.64 vs 0.74 hours, P = .044). CONCLUSIONS: MRI overestimated glenoid labrum tear size compared with intraoperative measurements and differed substantially between the 2 modalities on a case-by-case basis, with men displaying a larger discrepancy in measurement difference than women. These findings indicate that MRI may be more appropriately used as a categorical tool for confirming the presence of glenoid labral tears, rather than as a precise measure of tear size. LEVEL OF EVIDENCE: Level III, retrospective diagnostic case series.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical and radiological comparisons of posterior labral tears with and without posterior glenohumeral instability.Clinics in shoulder and elbow · 2026
- Diagnostic Musculoskeletal Ultrasound in the Evaluation of the Glenoid Labrum.International journal of sports physical therapy · 2026
- Evaluation of articular cartilage of the glenohumeral joint in patients with labral tears using T2 mapping technique on MRI: Is there a correlation between cartilage T2 values and labral tear location or frequency of shoulder dislocation?Skeletal radiology · 2026
- Diagnostic Accuracy of Magnetic Resonance Imaging Signs for Detecting Meniscal Root Tears: A Prospective Comparison with Arthroscopic Findings.Journal of orthopaedic case reports · 2026
- MRI-based assessment of greater tuberosity exposure in massive rotator cuff tears: a systematic review of current evidence and methodological gaps.BMC musculoskeletal disorders · 2026
- Intra- and Interobserver Reliability of the CT-Based Glenoid Arc-Angle Method Using Injured-Side and Contralateral Reference Circles: A Diagnostic Reliability Study.Diagnostics (Basel, Switzerland) · 2026