Neuroradiology

Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery.

Simon Beatty, Kalen Riley, Nicholas Deep, Nicholas Koontz

Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, USA. · Department of Radiology, Mayo Clinic Arizona, Phoenix, USA.

Observational · n=38

Key points

From the paper's conclusion
  • In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.

Abstract

PURPOSE: Failed stapes surgery presents a diagnostic challenge requiring high-resolution imaging to guide revision. Photon-counting CT (PCCT) offers improved spatial resolution and reduced noise compared with conventional energy-integrating detector CT (EID-CT). This study compared PCCT and EID-CT for identifying etiologies of failed primary stapes surgery, with emphasis on diagnostic accuracy, interobserver agreement, and interpreter confidence. METHODS: In this retrospective study, 38 patients with failed primary stapes surgery who underwent successful revision surgery and pre-revision CT were included; 18 underwent PCCT and 20 underwent EID-CT. Three expert reviewers independently determined the cause of surgical failure using intraoperative findings at revision as the reference standard. Diagnostic accuracy, interobserver agreement (Fleiss kappa), and reader confidence were compared between modalities. RESULTS: Overall interobserver agreement was higher with PCCT (κ = 0.75; 95% CI, 0.60-0.90) than EID-CT (κ = 0.44; 95% CI, 0.30-0.59), with non-overlapping confidence intervals for overall agreement and ossicular discontinuity. Consensus diagnostic accuracy did not significantly differ between modalities (88.9% PCCT vs. 85.0% EID-CT; p = 1.00), nor did interpreter confidence (4.33 vs. 4.17; p = 0.29). CONCLUSION: In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers