Photon-counting computed tomography improves interobserver agreement in the evaluation of failed stapes surgery.
Simon Beatty, Kalen Riley, Nicholas Deep, Nicholas Koontz
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic Arizona, Phoenix, USA. · Department of Radiology, Mayo Clinic Arizona, Phoenix, USA.
Key points
From the paper's conclusion- In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.
Abstract
PURPOSE: Failed stapes surgery presents a diagnostic challenge requiring high-resolution imaging to guide revision. Photon-counting CT (PCCT) offers improved spatial resolution and reduced noise compared with conventional energy-integrating detector CT (EID-CT). This study compared PCCT and EID-CT for identifying etiologies of failed primary stapes surgery, with emphasis on diagnostic accuracy, interobserver agreement, and interpreter confidence. METHODS: In this retrospective study, 38 patients with failed primary stapes surgery who underwent successful revision surgery and pre-revision CT were included; 18 underwent PCCT and 20 underwent EID-CT. Three expert reviewers independently determined the cause of surgical failure using intraoperative findings at revision as the reference standard. Diagnostic accuracy, interobserver agreement (Fleiss kappa), and reader confidence were compared between modalities. RESULTS: Overall interobserver agreement was higher with PCCT (κ = 0.75; 95% CI, 0.60-0.90) than EID-CT (κ = 0.44; 95% CI, 0.30-0.59), with non-overlapping confidence intervals for overall agreement and ossicular discontinuity. Consensus diagnostic accuracy did not significantly differ between modalities (88.9% PCCT vs. 85.0% EID-CT; p = 1.00), nor did interpreter confidence (4.33 vs. 4.17; p = 0.29). CONCLUSION: In this small cohort, PCCT demonstrated higher interobserver agreement than EID-CT without statistically significant differences in diagnostic accuracy or reader confidence, suggesting more reproducible assessment of failed stapes surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Photon-counting CT for preoperative assessment of stapes footplate fixation in otosclerosis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Photon-Counting CT for Postoperative Imaging of Cochlear Implants: Comparison to Flat-Detector CT.Investigative radiology · 2026
- Improved visualization of malpositioned middle ear prostheses using photon-counting detector CT: a cadaver study.Radiology advances · 2026
- Optimization of the reconstruction kernel for temporal bone imaging using photon-counting detector CT: A combined physical and visual evaluationRadiography · 2025
- Improved assessment of the cochlear implant and temporal bone structures with ultra-high resolution photon-counting detector CT compared to conventional CT systems.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Detection of structural failure in bridging stent grafts: photon-counting CT versus dual-energy CT in a controlled in vitro study.The Journal of cardiovascular surgery · 2026