Accurate determination of vitamin B12 in infant formula using isotope dilution-ultrahigh-performance liquid chromatography-tandem mass spectrometry.
Hyeonwoo Yu, Yared Getachew Lijalem, Jaehyoung Koo, Sangdoo Ahn, Byungjoo Kim, Kihwan Choi
Organic Metrology Group, Division of Chemical and Material Metrology, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of Korea. · Department of Chemistry, Chung-Ang University, Seoul, 06974, Republic of Korea.
Key points
From the paper's conclusion- A method for the accurate determination of vitamin B12 (cobalamin) in infant formula was developed using isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS).
Abstract
A method for the accurate determination of vitamin B12 (cobalamin) in infant formula was developed using isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). As an internal standard, a [13C7]-cyanocobalamin isotope-labeled analogue was used. Because of the hygroscopic property of cobalamins, the concentration of the cyanocobalamin standard solution was determined via quantitative nuclear magnetic resonance (qNMR) spectroscopy and further validated by capillary electrophoresis with ultraviolet detection as an independent technique. The cobalamins contained in infant formula were converted to cyanocobalamin in the presence of cyanide. Incomplete conversion of cobalamins was observed, and the residual amount of hydroxocobalamin was quantified to obtain the total amount of cobalamins. The expanded measurement uncertainty ranged from 1.7% to 2.4%, accounting for the contribution of residual hydroxocobalamin. Recovery, calculated by comparing the measured CN-Cbl concentration with the gravimetric fortification level, ranged from 101 to 103%. Both intra- and inter-day RSDs were below 1%. The method was applied to commercially available infant formula, with cobalamin concentrations ranging from 31.0 to 40.6 µg/kg.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vitamer-specific determination of vitamin B12 in food matrices: Analytical methodologies, challenges and future perspectives.Food chemistry · 2026
- A candidate reference measurement procedure based on isotope dilution-liquid chromatography-tandem mass spectrometry for standardizing human serum D-α-tocopherol measurements.Clinica chimica acta; international journal of clinical chemistry · 2026
- Evaluation and correction of charcoal-stripped serum matrix bias in stable-isotope-dilution LC-MS/MS quantification of endogenous serum folates.Analytical and bioanalytical chemistry · 2026
- Holotranscobalamin-based algorithm for the identification of macro-vitamin B12 in analytical hypercobalaminemiaClinica Chimica Acta · 2026
- Vitamin B12 and one-carbon biomarker assay interference: a systematic review, with a consensus-derived diagnostic algorithm proposed for Gulf primary careFrontiers in Molecular Biosciences · 2026
- Interference by macro-B12: multicenter evaluation of polyethylene glycol precipitation and establishment of reference intervals using four different immunoassay methodsAdvances in Laboratory Medicine / Avances en Medicina de Laboratorio · 2026