Updated glucose management indicator (GMI) better aligns with HbA1c than current GMI: implications for clinical practice and reporting
Richard M. Bergenstal, Yongjin Xu, Timothy C. Dunn, Pratik Choudhary, Ramzi Ajjan
HealthPartners · Diabetes Care Center
Key points
From the paper's conclusion- Compared with the CGM-derived GMI, the uGMI provides more accurate and consistent agreement with HbA1c, particularly at lower (<42mmol/mol or 6% NGSP) and higher (>58 mmol/mol or 7.5% NGSP) HbA1c levels.
Abstract
The continuous glucose monitoring (CGM)-derived glucose management indicator (GMI) is valuable to people with diabetes, and healthcare professionals and organisations for assessing overall glucose levels, optimising management plans. However, the current GMI can both over- and underestimate HbA1c, which can create clinical difficulties. Our aim was to improve the agreement between these two markers across clinically relevant ranges of glucose. An updated GMI (uGMI) model based on physiological processes was evaluated using clinical trial and real-world data. The empirical relationship between average glucose (AG) and HbA1c was evaluated over 100 equal-sized data bins ordered by the sum of their rank positions. Alignments were assessed using biases in various ranges. In 18,860 individuals with 26,647 AG–HbA1c pairs, the uGMI significantly improved alignment with HbA1c and reduced the proportion of pairs with clinically significant discordance. Specifically, the regression slope of HbA1c vs GMI decreased from 1.4 to 1.0 when using uGMI, effectively eliminating proportional bias by reducing the deviation from unity (p<0.0001). Furthermore, absolute bias at HbA1c below 31 mmol/mol (5.5% in National Glycohemoglobin Standardization Program [NGSP]) and above 75 mmol/mol (9.0% NGSP) was reduced from >4.4 mmol/mol (0.4% NGSP) to ≤1.1 mmol/mol (0.1% NGSP). Consistent performance across both Abbott Freestyle Libre and Dexcom CGM devices confirmed that the uGMI is robust and device-independent, supporting its clinical utility and incorporation into standardised CGM clinical summary reports. Compared with the CGM-derived GMI, the uGMI provides more accurate and consistent agreement with HbA1c, particularly at lower (<42mmol/mol or 6% NGSP) and higher (>58 mmol/mol or 7.5% NGSP) HbA1c levels.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes.Diabetes, obesity & metabolism · 2026
- Differences in the Glucose Management Indicator Between Continuous Glucose Monitoring Systems.Diabetes, obesity & metabolism · 2026
- Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetesPLOS Digital Health · 2026
- Association of HbA1c and an updated glucose management indicator (uGMI) with incident diabetic retinopathy in adults with type 1 diabetes: a longitudinal studyDiabetologia · 2025
- High-Amplitude and Prolonged Glucose Excursions as a Key Determinant of Discordance Between Glucose Management Indicator and Glycated Hemoglobin in Type 1 DiabetesDiabetes Care · 2026
- Beyond the glycation gap: A multicompartment framework for HbA1c-glycemia discordance in Pediatric type 1 diabetes.Clinica chimica acta; international journal of clinical chemistry · 2026