Narrowing the A1c gap: Personalized modeling of HbA1c– continuous glucose monitor discordance in type 1 diabetes
Simon Lebech Cichosz, Camilla Heisel Nyholm Thomsen, David C. Klonoff, Irl B. Hirsch, Morten Hasselstrøm Jensen
Aalborg University · Mills Peninsula Health Services
Key points
From the paper's conclusion- This study aims to characterize the temporal discordance between CGM-derived glucose exposure and HbA1c over time in individuals with type 1 diabetes, and to explore the development of a statistical model to adjust the relationship between these measures based on previously observed individual discrepancies.
Abstract
This study aims to characterize the temporal discordance between CGM-derived glucose exposure and HbA1c over time in individuals with type 1 diabetes, and to explore the development of a statistical model to adjust the relationship between these measures based on previously observed individual discrepancies. We paired CGM-data in a 60-day window prior to each HbA1c measurement and included individuals with type 1 diabetes with multiple pairs to assess and model discordance over time. Discordance was defined as difference between HbA1c and Glucose Management Indicator at each pair. At baseline (first pair), participants were categorized into three groups based on the degree of discordance: positive (≥0.5%), negative (≤-0.5%), and neutral (within ±0.5%). A multiple linear regression model incorporating historical discordance values, HbA1c levels, and the current GMI was utilized for an adjustment. 477 individuals were included and 1,523 instances of paired HbA1c and CGM-data were analyzed. Absolute discordance of ≥0.5% was observed in 31% of cases. In 51% of instances, the direction of discordance in each pair was maintained. In the modeling analysis, GMI accounted for 69% of the variance in HbA1c levels (r = 0.83, p < 0.001, MAE = 0.42%). Adjusting improved variance explainability to 82% (r = 0.90, p < 0.001, MAE = 0.33%). HbA1c-CGM discordance is highly prevalent, and while inter-individual discordance shows some degree of persistence, it also appears to vary over time for a substantial proportion of individuals. Adjusting for individual discordance in the short term can improve the alignment between adjusted GMI and laboratory-measured HbA1c.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond the glycation gap: A multicompartment framework for HbA1c-glycemia discordance in Pediatric type 1 diabetes.Clinica chimica acta; international journal of clinical chemistry · 2026
- Determinants of Discordance between Estimated and Measured HbA1c: The Role of Active Time in 14-Day Continuous Glucose Monitoring Data.Diabetes & metabolism journal · 2026
- High-Amplitude and Prolonged Glucose Excursions as a Key Determinant of Discordance Between Glucose Management Indicator and Glycated Hemoglobin in Type 1 DiabetesDiabetes Care · 2026
- Updated glucose management indicator (GMI) better aligns with HbA1c than current GMI: implications for clinical practice and reportingDiabetologia · 2026
- A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes.Diabetes, obesity & metabolism · 2026
- Glycemic Variability Bridges Time in Range and Time in Tight Range: A Unified Equation for Both Type 1 and Type 2 Diabetes Based on Large‐Scale Continuous Glucose Monitoring DataDiabetes Obesity and Metabolism · 2026