Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement - a biomechanical human cadaveric study.
Adrian Deichsel, Arian Große-Allermann, Klemens Horst, Christoph Kittl, Moritz Lodde, Boyko Gueorguiev, Ludmil Drenchev, Hristo K Skulev,
Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert- Schweitzer-Campus 1, 48149, Münster, Germany. adrian.deichsel@ukmuenster.de. · Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert- Schweitzer-Campus 1, 48149, Münster, Germany.
Key points
From the paper's conclusion- An additional McLaughlin cerclage reduced interfragmentary displacement in distal patellar pole fractures. In cases of unstable distal pole patella fractures, the additional use of a McLaughlin cerclage may therefore be considered to enhance construct stability.
Abstract
PURPOSE: To investigate whether the addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures provides improved biomechanical construct stability and reduced interfragmentary displacement. METHODS: A distal patellar pole fracture was simulated in sixteen fresh-frozen human cadaveric knees by a horizontal osteotomy in the distal third of the patella. Subsequently, locking plate fixation was performed. In a randomized half of the specimens, an additional McLaughlin wire cerclage was applied. The specimens were then subjected to 3000 cycles of extension starting at 90° of flexion under a maximum tensile load of 320 N. Using a Digital Image Correlation (DIC) system, the interfragmentary displacement between the proximal and distal fragments was measured at 1, 10, 20, 30, 50, 100, 500, 1000, 2000, and 3000 cycles. Statistical analysis was performed using repeated-measures ANOVA and Welch's unpaired t-t test at 3000 cycles. RESULTS: An additional McLaughlin cerclage significantly reduced interfragmentary displacement under cyclic loading in comparison to locking plate fixation alone. After 3000 cycles, displacement was 2.27 ± 1.84 mm with plate fixation alone and 0.36 ± 0.22 mm with additional McLaughlin cerclage (mean difference 1.91 mm; 95% CI 0.38-3.45 mm; p = 0.0215). CONCLUSION: An additional McLaughlin cerclage reduced interfragmentary displacement in distal patellar pole fractures. In cases of unstable distal pole patella fractures, the additional use of a McLaughlin cerclage may therefore be considered to enhance construct stability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial.The bone & joint journal · 2026
- Biomechanical and finite element analysis of a novel annular multi-axial locking plate for patellar fracture fixation.Journal of orthopaedic surgery and research · 2026
- Modified Multi-Strand Nice Knot Suture Construct Combined with Suture Anchor Fixation Versus Conventional Kirschner Wire Tension Band Fixation for Inferior Patellar Pole Fractures: A Retrospective Comparative Study.Journal of clinical medicine · 2026
- Combined Cerclage and Figure-of-eight Tension-band Wiring without K-wire Versus K-wire Tension Band Wiring Fixation for Transverse Patellar Fractures: A Prospective Comparative Study.Journal of orthopaedic case reports · 2026
- Nitinol continuous-compression staple fixation for selected complex patella fractures: a technical note.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Biomechanical Comparison of Patellar Fixation Techniques in Medial Patellofemoral Ligament Reconstruction: A Pediatric Cadaveric Study.Orthopaedic journal of sports medicine · 2026