Biomechanical Comparison of Patellar Fixation Techniques in Medial Patellofemoral Ligament Reconstruction: A Pediatric Cadaveric Study.
Bryan Khoo, Henry B G Baird, Jude Alawa, Amin Alayleh, Thomas Johnstone, Calvin Chan, Kevin G Shea
Pediatric Orthopaedic Surgery, Stanford University, Stanford, California, USA. · Department of Orthopaedic Surgery, University of Virginia Health System, Charlottesville, Virginia, USA.
Key points
From the paper's conclusion- In this pediatric cadaveric model, BT fixation demonstrated higher ultimate failure loads than the SA fixation, while construct stiffness was similar between techniques.
Abstract
BACKGROUND: The biomechanical properties of different medial patellofemoral ligament (MPFL) reconstruction (MPFLR) techniques have been described in adult cadaveric models. However, little is known about the biomechanical properties of these techniques in pediatric specimens. PURPOSE: To (1) evaluate the biomechanical fixation strength of pediatric patellae in the context of MPFLR and (2) compare the performance of suture-anchor (SA) and bone-tunnel (BT) patellar fixation. STUDY DESIGN: Controlled laboratory study. METHODS: Ten pediatric cadaveric patellae from 6 donors (3 male and 3 female, mean 9.8 + 0.75 years, range 9-11 years) were utilized. For the all-SA group, two 1.8-mm all-SA, each loaded with sutures, were placed on the medial side of the patella at the articular cartilage margin. For the BTs, two 2-mm tunnels were drilled from the medial side of the patella to the anterior patellar surface. No. 2 braided suture was then passed through the tunnels. Both constructs were loaded into a servomechanical testing apparatus, and a suture was tied to the top frame such that pullout would be in the same plane as the fixation construct, oriented to approximate the plane of the native MPFL insertion. RESULTS: BT constructs demonstrated a mean ultimate failure load of 169.8 ± 88.6 N, significantly higher than the 55.3 ± 20.1 N observed for SA constructs (P = .002). No significant difference in stiffness was found between BT (6 ± 1.9 N/mm) and SA (6.4 ± 1.7 N/mm; P = .647). The mechanisms of failure were anchor pullout for all SAs and suture cheese-wiring for all BTs. CONCLUSION: In this pediatric cadaveric model, BT fixation demonstrated higher ultimate failure loads than the SA fixation, while construct stiffness was similar between techniques. CLINICAL RELEVANCE: To our knowledge, this is the first biomechanical study of MPFL patellar fixation reconstruction techniques performed in pediatric specimens. To reduce the risk of patellar graft fixation failure, the relatively low load-to-failure of all-SA fixation demonstrated in this study may be considered when treating pediatric patients with lower bone density. Moreover, biomechanically superior small-diameter oblique BTs with low fracture risk may be considered to maximize time-zero fixation strength compared with SAs in the pediatric population. However, these results are limited by evaluating only a single all-SA design and a testing methodology that focused on time-zero fixation strength, without cyclic loading or in vivo healing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes of femoral bone tunnel fixation and onlay fixation techniques for medial patellofemoral ligament reconstruction: a systematic review.The Knee · 2026
- Patellar fixation in MPFL reconstruction: a network meta-analysis comparing bone tunnel and suture anchor techniques.Journal of orthopaedic surgery and research · 2026
- Medial Patellofemoral Ligament Reconstruction With Transverse Reefing (Tubing) of Medial Patellar Retinaculum and Biological Fixation.Arthroscopy techniques · 2026
- Double Adjustable-Loop Cortical Buttons for Minimally Invasive Anatomic Double-Bundle Medial Patellofemoral Ligament Reconstruction.Arthroscopy techniques · 2026
- Rethinking MPFL Graft Tensioning: A Conceptual Framework for Anatomy-Driven Dynamic Tensioning Beyond Force and Flexion Angle.Medicina (Kaunas, Lithuania) · 2026
- Arthroscopic Physeal-Sparing Suture-Anchor Fixation for Pediatric Femoral-Side Posterior Cruciate Ligament Avulsion.Arthroscopy techniques · 2026