Combined Cerclage and Figure-of-eight Tension-band Wiring without K-wire Versus K-wire Tension Band Wiring Fixation for Transverse Patellar Fractures: A Prospective Comparative Study.
Akshay V Pawar, Mohan M Desai, Kapil A Pawar
Department of Orthopedics, Seth Gordhandas Sunderdas Medical College and King Edward Memorial Hospital, Mumbai, Maharashtra, India.
Key points
From the paper's conclusion- The study demonstrates that combined cerclage TBW without K-wires provides functional outcomes comparable to those of conventional modified TBW with K-wires at 1 year, while potentially reducing K-wire-related complications such as implant migration, prominence, irritation, and subsequent implant removal surgery.
Abstract
INTRODUCTION: Conventional modified tension-band wiring (TBW) using Kirschner wires (K-wires) is widely used for displaced transverse patellar fractures but is associated with implant prominence, irritation, migration, and breakage. K-wire-free fixation using combined cerclage and TBW may provide stable fixation while reducing hardware-related complications. MATERIALS AND METHODS: Prospective comparative study of 156 patients with transverse patella fracture with follow-up of at least 18 months. Group A consisted of 82 patients treated with K-wire TBW and Group B consisted of 74 patients treated with combined cerclage TBW without K-wires. Clinical assessment was done by knee range of motion, extension lag, and presence of local tenderness. Pain assessment was done using the Visual Analog Scale. Functional assessment was performed using the Bostman knee score. Radiological assessment was done using standard radiographs of the knee. Complications and implant removal were also assessed. The Chi-square test, Fisher's exact test, and independent-samples t-test were used to assess association. P < 0.05 was considered satistically significant. RESULTS: Both groups were comparable in demographics such as age, gender, body mass index, and follow-up period. The combined cerclage TBW without K-wires group demonstrated significantly lower pain scores at 6 weeks, 3 months, and 6 months and less knee tenderness at 6 weeks and 3 months. Bostman scores were significantly higher at 6 months and 1 year. The pain and stair-climbing components of the Bostman score were significantly better in the combined cerclage group at 6 months and 1 year. Implant migration/breakage (2% vs. 17%) and hardware irritation (10% vs. 17%) were significantly reduced with combined cerclage TBW. Implant removal preference (16% vs. 43%) and actual removal surgery (13% vs. 31%) were also significantly lower. CONCLUSION: The study demonstrates that combined cerclage TBW without K-wires provides functional outcomes comparable to those of conventional modified TBW with K-wires at 1 year, while potentially reducing K-wire-related complications such as implant migration, prominence, irritation, and subsequent implant removal surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Divergent K-wires in the sagittal plane have minimal impact on fixation stability and the resulting early clinical outcomes in patients with transverse patellar fractures.BMC musculoskeletal disorders · 2026
- Modified Multi-Strand Nice Knot Suture Construct Combined with Suture Anchor Fixation Versus Conventional Kirschner Wire Tension Band Fixation for Inferior Patellar Pole Fractures: A Retrospective Comparative Study.Journal of clinical medicine · 2026
- Clinical outcomes of contoured dorsal mini-fragment plate fixation versus tension band wiring for transverse articular patellar fractures: a prospective observational study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Modified non-transarticular K-wire external fixation versus traditional transarticular pinning for bony mallet finger: a prospective comparative cohort study.Journal of plastic surgery and hand surgery · 2026
- Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial.The bone & joint journal · 2026
- Biomechanical comparison of modified tension band wiring using Kirschner wires with eyelets and conventional tension band wiring for olecranon fractures: A composite bone study.Clinical biomechanics (Bristol, Avon) · 2026