Veterinary Record Case Reports

Internal fixation of a comminuted femoral neck fracture using pins and a conventional plate in a dog with multiple orthopaedic injuries

Chloe Job, Alexandre Guillemot

Key points

From the paper's conclusion
  • In this case, an LCP plate was used as a conventional plate to increase construct strength because of the size of the dog and the several orthopaedic injuries.

Abstract

A one‐and‐a‐half‐year‐old, entire, male Rottweiler was presented for evaluation of a nonambulatory state following a hit‐by‐car injury. A right extracapsular basilar closed comminuted femoral neck fracture was diagnosed. The fracture was stabilised using two Steinmann pins and a 2‐mm locking compression plate (LCP) used as a conventional plate. No complications were noted in the immediate postoperative period. Follow‐up evaluations at 1, 2 and 11 months revealed a normal orthopaedic examination without radiographic evidence of complications. Femoral neck fractures are commonly stabilised using screws or pins. Reported complications include implant breakage, migration or neck resorption. In this case, an LCP plate was used as a conventional plate to increase construct strength because of the size of the dog and the several orthopaedic injuries. Plate constructs seem to be a feasible and effective option for stabilisation of femoral neck fractures in large‐breed dogs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Internal fixation of a comminuted femoral neck fracture using pins and a conventional plate in a dog with multiple orthopaedic injuries — Science Skim