Good outcome can be achieved by femoral neck system with a supplementary Pauwels screw for unstable Pauwels type III femoral neck fractures in less than 65 years old adults.
Chun Yu Wu, Chun Yu Chen, Kai Cheng Lin
Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan. · Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan. orthokcl@gmail.com.
Key points
From the paper's conclusion- In this preliminary series, FNS supplemented with a perpendicular Pauwels screw was technically feasible; all fractures united and 7 of 10 healed with no more than mild (≤ 5 mm) shortening, although varus collapse occurred in one patient, AVN in one and screw back-out in two. Without a control group these results cannot be attributed to the supplementary screw, and comparative studies with longer follow-up are needed.
Abstract
BACKGROUND: Pauwels type III femoral neck fractures in adults younger than 65 years are usually caused by high-energy trauma, are loaded predominantly in vertical shear, and carry high rates of nonunion, fixation failure and avascular necrosis (AVN). The Femoral Neck System (FNS) provides angular and rotational stability, but in this pattern, particularly with posteromedial comminution, standalone FNS is still followed by substantial femoral neck shortening, which is associated with inferior hip function. We therefore added a supplementary Pauwels screw placed approximately perpendicular to the fracture line. This preliminary case series describes the technique and its early outcomes, with union with no more than mild (≤ 5 mm) shortening as the primary outcome. METHODS: Since March 2024, we have used FNS with an additional Pauwels screw for unstable Pauwels type III femoral neck fractures in patients younger than 65 years. Closed reduction was performed on a fracture table, and limited open reduction was added when required. After anatomical or near-anatomical reduction, a standard FNS was implanted first, and a single supplementary cannulated screw was then inserted from the middle-to-lower greater trochanter towards the central-inferior femoral head, crossing the fracture line as close to 90° as possible. Patients were kept non-weight-bearing for at least 6 weeks. Femoral neck shortening, the primary outcome, was graded as none or mild (≤ 5 mm), moderate (5-10 mm) or severe (> 10 mm). Construct-related mechanical complications, comprising FNS implant failure, loss of reduction and back-out of the Pauwels screw, were recorded, and hip function was assessed with the Harris Hip Score (HHS). RESULTS: All ten fractures were displaced Pauwels type III fractures (Garden type III, n = 1; Garden type IV, n = 9). Mean age was 42.3 ± 12.3 years and mean follow-up 18.0 ± 5.3 months. Mean operative time was 102.11 ± 42.20 min, blood loss 111.00 ± 74.75 mL and hospital stay 4.10 ± 1.91 days. Three patients had a comminuted posteromedial cortex on preoperative CT. All ten fractures united, at a mean of 118.44 ± 54.63 days. Mean femoral neck shortening was 2.87 ± 3.65 mm; the primary outcome, union with no more than mild shortening, was achieved in 7 of 10 patients (95% CI 35-93%), and two had moderate and one severe shortening. Construct-related mechanical complications occurred in 2 of 10 patients - back-out of the Pauwels screw in both, with 7° of varus collapse in one - and no FNS implant failure occurred; both backed-out screws were removed after union. AVN developed in 1 of 10 patients, and no patient required conversion to arthroplasty. The mean HHS was 93.08 ± 6.63 at the latest clinic follow-up and 90.61 ± 6.61 at a telephone interview, with excellent-to-good results in 9 of 10 patients at both assessments. CONCLUSION: In this preliminary series, FNS supplemented with a perpendicular Pauwels screw was technically feasible; all fractures united and 7 of 10 healed with no more than mild (≤ 5 mm) shortening, although varus collapse occurred in one patient, AVN in one and screw back-out in two. Without a control group these results cannot be attributed to the supplementary screw, and comparative studies with longer follow-up are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of variable bolt position of femoral neck system on Pauwels III fractures with superior femoral neck bone defect: multimodal biomechanical and clinical study.Frontiers in surgery · 2026
- Femoral Neck Antirotation and Support System: A Novel Internal Fixation for Pauwels III Femoral Neck Fractures: A Finite Element Analysis.Indian journal of orthopaedics · 2026
- Targeted Fully-Threaded Screw Augmentation with the Femoral Neck System Reduces Neck Shortening and Posterior Tilt, Leading to Improved Function in Geriatric Garden I-II Femoral Neck Fractures: A Retrospective Comparative Study.Clinics in orthopedic surgery · 2026
- Femoral Neck System for young and middle-aged adult femoral neck fractures: a trade-off between reduced lateral irritation and increased neck shortening.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Functional Outcome of Femoral Neck Fractures with Posterior Comminution Managed by Dynamic Hip Screw with Fibular Strut Grafting: A Case Series Study.Journal of orthopaedic case reports · 2026
- Early clinical and radiographic outcomes of robot-assisted femoral neck system fixation combined with an additional cannulated compression screw for garden IV femoral neck fractures in young and middle-aged adults: a propensity score-matched retrospective cohort study.Frontiers in surgery · 2026